EUVIMEDOntdek EUVIMED
Open access · CC BY 4.0

Electromechanical and Acoustic Characterization of Dual-Mode Rectangular PMUT

Yumna Birjis, Arezoo Emadi

Microelectronics · 2026-04-09 · 2 (2) · 6

DOI: 10.3390/microelectronics2020006 ↗

At a glance

Journal article in Microelectronics, published online on 2026-04-09. Written by Yumna Birjis and 1 co-authors. 30 references. The full text is freely available (open access, CC BY 4.0). Funded by: Windsor Cancer Centre Foundation and WE-SPARK Health Institute, Natural Sciences and Engineering Research Council of Canada, CMC Microsystems.

SamenvattingBibliografische gegevensCiteRelated studies

Abstract (original language)

Multifrequency operation in micromachined ultrasonic transducers, enabled by targeted excitation of specific vibrational modes, has emerged as an attractive approach for achieving tunable performance and configurability, well-suited for advanced ultrasound imaging and therapeutic applications. This paper presents a dual-electrode rectangular piezoelectric micromachined ultrasonic transducer (PMUT) designed for efficient dual-frequency operation through mode-selective actuation. The proposed architecture employs segmented electrodes that are spatially aligned with the strain distributions of two distinct flexural modes, enabling selective excitation of Mode 1 (fundamental) and Mode 3 (higher order) through appropriate electrode actuation. Finite element simulations and impedance analysis were used to guide the electrode configuration and validate the mode-selective behavior. The dual-mode PMUT was fabricated alongside a conventional single-electrode PMUT using identical membrane dimensions and material stack for direct comparison. Comprehensive electrical and underwater acoustic characterization confirmed that the conventional PMUT is limited to single-frequency operation at the fundamental resonance. In contrast, the proposed design achieved a substantial improvement in higher-order performance, with a threefold increase in acoustic pressure at Mode 3 compared to the conventional device. These results demonstrate that mode-aligned electrode segmentation enables efficient dual-mode operation without added fabrication complexity, making the design highly suitable for multifrequency ultrasonic applications such as biomedical imaging and sensing.

Funding

  • Windsor Cancer Centre Foundation and WE-SPARK Health Institute
  • Natural Sciences and Engineering Research Council of Canada
  • CMC Microsystems
  • University of Windsor Office of Research & Innovation Services

Cite

APA

Birjis, Y., & Emadi, A. (2026). Electromechanical and Acoustic Characterization of Dual-Mode Rectangular PMUT. Microelectronics, 2(2), 6. https://doi.org/10.3390/microelectronics2020006

Vancouver

Birjis Y, Emadi A. Electromechanical and Acoustic Characterization of Dual-Mode Rectangular PMUT. Microelectronics. 2026;2(2):6. doi:10.3390/microelectronics2020006

BibTeX
@article{Birjis2026,
  author = {Birjis, Yumna and Emadi, Arezoo},
  title = {Electromechanical and Acoustic Characterization of Dual-Mode Rectangular PMUT},
  journal = {Microelectronics},
  year = {2026},
  volume = {2},
  number = {2},
  pages = {6},
  doi = {10.3390/microelectronics2020006}
}
Start for free →