Computer-Controlled Balloon Manometry Coupled with Inverse Finite Element Analysis for Assessing Chronic Radiation-Induced Rectal Injury in Rats
Micromachines · 16.11.2026 · 17 (11) · 1329
DOI: 10.3390/mi17111329 ↗Kurz gefasst
Fachartikel in der Zeitschrift Micromachines, online erschienen am 16.11.2026. Verfasst von Jing Zhang und 14 weiteren Autor:innen. Die Arbeit nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, China Postdoctoral Science Foundation, Key Clinical Specialty Project of Shanghai.
Abstract (Originalsprache)
Quantitative assessment of chronic radiation-induced rectal injury (RRI) requires methods that relate tissue remodeling to mechanical function. We integrated computer-controlled balloon manometry, inverse finite element analysis, and paired whole-wall histopathology in a preclinical exploratory workflow. Male Sprague–Dawley rats received 0, 12, 20, or 28 Gy pelvic irradiation and were assessed at 3–4 months. Of 32 enrolled rats, 29 contributed tissue assessments and 26 yielded paired mechanical and histopathological data. Balloon-corrected pressure–volume curves were analyzed with a three-parameter Yeoh model using a common axisymmetric geometry. The recorded coefficient c10 and the post hoc index cmax = max(c10, c20) were associated with injury scores (Spearman ρ = 0.5955 and 0.6675, respectively). Differences from correlations for selected pressure measures were not formally tested. Higher cmax also accompanied edema, fibrosis, and vascular stenosis in exploratory comparisons. Model-archive inspection identified a nearly incompressible formulation and an inconsistency between the radius used in the fitted volume expression and the geometric radius. The outputs have not been recomputed; the coefficients remain provisional descriptors of the archived workflow. The contribution is the integration of controlled loading with a histological reference. Selective testability, unvalidated loading safety, the volume-definition discrepancy, and unestablished parameter identifiability prevent interpretation as validated tissue stiffness or clinical performance.
Förderung
- National Natural Science Foundation of China
- China Postdoctoral Science Foundation
- Key Clinical Specialty Project of Shanghai
Zitieren
APA
Zhang, J., Lin, Y., Jin, X., Xie, M., Ma, X., Deng, Y., Huang, B., Zhang, H., He, L., Lv, Z., Zhang, Z., Lin, L., Zeng, Y., Xia, F., & Zhang, Z. (2026). Computer-Controlled Balloon Manometry Coupled with Inverse Finite Element Analysis for Assessing Chronic Radiation-Induced Rectal Injury in Rats. Micromachines, 17(11), 1329. https://doi.org/10.3390/mi17111329
Vancouver
Zhang J, Lin Y, Jin X, Xie M, Ma X, Deng Y, et al. Computer-Controlled Balloon Manometry Coupled with Inverse Finite Element Analysis for Assessing Chronic Radiation-Induced Rectal Injury in Rats. Micromachines. 2026;17(11):1329. doi:10.3390/mi17111329
BibTeX
@article{Zhang2026,
author = {Zhang, Jing and Lin, Yingxuan and Jin, Xin and Xie, Mingzhu and Ma, Xuejun and Deng, Yun and Huang, Ben and Zhang, Hui and He, Luoxi and Lv, Zonglin and Zhang, Zhiyuan and Lin, Long and Zeng, Yuting and Xia, Fan and Zhang, Zhen},
title = {Computer-Controlled Balloon Manometry Coupled with Inverse Finite Element Analysis for Assessing Chronic Radiation-Induced Rectal Injury in Rats},
journal = {Micromachines},
year = {2026},
volume = {17},
number = {11},
pages = {1329},
doi = {10.3390/mi17111329}
}