EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

An Ultraminiature Pressure Sensor Integrated into Acupuncture Needle Tip for In Vivo Monitoring of Local Muscle Response

Ci Song, Zheng Yu, Xiaohong Chen, Xiaojing Liu, Wei Li, Zao Ni, Shuguang Yu, Xinxin Li

Micromachines · 30.10.2026 · 17 (11) · 1256

DOI: 10.3390/mi17111256 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Micromachines, online erschienen am 30.10.2026. Verfasst von Ci Song und 7 weiteren Autor:innen. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Real-time monitoring of local muscle response during acupuncture could reveal mechanisms underlying acupuncture and provide objective feedback to support more precise needle control. However, the small dimensions of acupuncture needles impose stringent constraints on sensor miniaturization and packaging. This study presents an ultraminiature pressure sensor integrated into the tip of a 450-μm-diameter acupuncture needle. The sensor measures 200 × 1250 × 50 μm3 and incorporates an elongated pressure-sensitive diaphragm. Wafer-level AuSn solder deposition and thermocompression soldering connect the chip to an ultrafine wire ribbon routed through the 230-μm-diameter needle lumen. A 1.3-μm-thick Parylene C coating provides electrical insulation. After coating, the sensor exhibited a sensitivity of 40.3 μV/kPa at a 3.3 V excitation, retaining 78.4% of its uncoated sensitivity. Characterization over 90–150 kPa absolute and 25–45 °C yielded a maximum nonlinearity of approximately 0.73% of full scale (FS). The coated sensor exhibited a maximum hysteresis of 2.52% FS. In vivo experiments at the Zusanli acupoint in rats recorded pressure variations during thrusting–lifting manipulation. These results demonstrate the feasibility of monitoring local muscle response during acupuncture and their potential to provide quantitative feedback for needle manipulation.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Song, C., Yu, Z., Chen, X., Liu, X., Li, W., Ni, Z., Yu, S., & Li, X. (2026). An Ultraminiature Pressure Sensor Integrated into Acupuncture Needle Tip for In Vivo Monitoring of Local Muscle Response. Micromachines, 17(11), 1256. https://doi.org/10.3390/mi17111256

Vancouver

Song C, Yu Z, Chen X, Liu X, Li W, Ni Z, et al. An Ultraminiature Pressure Sensor Integrated into Acupuncture Needle Tip for In Vivo Monitoring of Local Muscle Response. Micromachines. 2026;17(11):1256. doi:10.3390/mi17111256

BibTeX
@article{Song2026,
  author = {Song, Ci and Yu, Zheng and Chen, Xiaohong and Liu, Xiaojing and Li, Wei and Ni, Zao and Yu, Shuguang and Li, Xinxin},
  title = {An Ultraminiature Pressure Sensor Integrated into Acupuncture Needle Tip for In Vivo Monitoring of Local Muscle Response},
  journal = {Micromachines},
  year = {2026},
  volume = {17},
  number = {11},
  pages = {1256},
  doi = {10.3390/mi17111256}
}