Study on Differential Pressure Flow Monitoring Based on Fiber Optic Temperature–Pressure Integrated Sensor

Qiang Zou, Xinglin Tong, Xiuwen Hong, Yunfeng Jia

IEEE Sensors Journal · 01.04.2026 · 26 (7) · 9826-9833

DOI: 10.1109/jsen.2025.3579877 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Sensors Journal, erschienen am 01.04.2026. Verfasst von Qiang Zou und 3 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 25 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Yangtze River Water Science Research Joint Fund.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The aim of this study is to precisely monitor the temperature, pressure, and flow in pipelines using a fiber optic FBG temperature–pressure integrated sensor, which will improve the accuracy and stability of flow monitoring and provide reliable data for assessing the health condition of the pipeline. The study includes the design and fabrication of a temperature–pressure integrated sensor, which is distributed on both sides of the throttling orifice plate to monitor the temperature and pressure. The difference in pressure across the throttling orifice plate is then used to calculate the real-time flow within the pipeline. The sensor, according to this monitoring scheme, has a temperature operating range of 0 °C–50 °C and a pressure operating range of 0–1 MPa. Experimental results showed that the maximum error in flow monitoring was 4.34% < 5%, meeting the error criteria. Compared with traditional differential pressure sensors, the temperature–pressure integrated sensor can monitor pipeline internal temperature and pressure during flow measurement and adapt more effectively to stress fatigue cycles. This feature prevents potential misjudgments of the system status that result from monitoring flow solely, thus validating its high reliability in flow monitoring.

Förderung

  • National Natural Science Foundation of China
  • Yangtze River Water Science Research Joint Fund

Zitieren

APA

Zou, Q., Tong, X., Hong, X., & Jia, Y. (2026). Study on Differential Pressure Flow Monitoring Based on Fiber Optic Temperature–Pressure Integrated Sensor. IEEE Sensors Journal, 26(7), 9826-9833. https://doi.org/10.1109/jsen.2025.3579877

Vancouver

Zou Q, Tong X, Hong X, Jia Y. Study on Differential Pressure Flow Monitoring Based on Fiber Optic Temperature–Pressure Integrated Sensor. IEEE Sensors Journal. 2026;26(7):9826-9833. doi:10.1109/jsen.2025.3579877

BibTeX
@article{Zou2026,
  author = {Zou, Qiang and Tong, Xinglin and Hong, Xiuwen and Jia, Yunfeng},
  title = {Study on Differential Pressure Flow Monitoring Based on Fiber Optic Temperature–Pressure Integrated Sensor},
  journal = {IEEE Sensors Journal},
  year = {2026},
  volume = {26},
  number = {7},
  pages = {9826--9833},
  doi = {10.1109/jsen.2025.3579877}
}