A Novel Polysilicon-Fill-Strengthened Etch-Through 3D Trench Electrode Detector: Fabrication Methods and Electrical Property Simulations
Micromachines · 06.08.2025 · 16 (8) · 912
DOI: 10.3390/mi16080912 ↗Kurz gefasst
Fachartikel in der Zeitschrift Micromachines, online erschienen am 06.08.2025. Verfasst von Xuran Zhu und 7 weiteren Autor:innen. Beteiligte Einrichtung: School of Integrated Circuits, Ludong University, Yantai 264025, China. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: This research were funded by the National Key Research and Development Program of China., National Key R&D Program of China, Key Project of the National Natural Science Foundation of China.
Abstract (Originalsprache)
Three-dimensional trench electrode silicon detectors play an important role in particle physics research, nuclear radiation detection, and other fields. A novel polysilicon-fill-strengthened etch-through 3D trench electrode detector is proposed to address the shortcomings of traditional 3D trench electrode silicon detectors; for example, the distribution of non-uniform electric fields, asymmetric electric potential, and dead zone. The physical properties of the detector have been extensively and systematically studied. This study simulated the electric field, potential, electron concentration distribution, complete depletion voltage, leakage current, capacitance, transient current induced by incident particles, and weighting field distribution of the detector. It also systematically studied and analyzed the electrical characteristics of the detector. Compared to traditional 3D trench electrode silicon detectors, this new detector adopts a manufacturing process of double-side etching technology and double-side filling technology, which results in a more sensitive detector volume and higher electric field uniformity. In addition, the size of the detector unit is 120 µm × 120 µm × 340 µm; the structure has a small fully depleted voltage, reaching a fully depleted state at around 1.4 V, with a saturation leakage current of approximately 4.8×10−10A, and a geometric capacitance of about 99 fF.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Integrated Circuits, Ludong University, Yantai 264025, China.
- Engineering Research Center of Photo Detector Special Chip in Universities of Shandong, Ludong University, Yantai 264025, China.
- School of Materials Science and Engineering, Xiangtan University, Xiangtan 411105, China.
- Institute of Microelectronics, Chinese Academy of Sciences, Beijing 100029, China.
ORCID-Profile: Tao Long, Jun Zhao, Manwen Liu, Meishan Wang
Förderung
- This research were funded by the National Key Research and Development Program of China.
- National Key R&D Program of China
- Key Project of the National Natural Science Foundation of China
Zitieren
APA
Zhu, X., Li, Z., Liu, Z., Long, T., Zhao, J., Li, X., Liu, M., & Wang, M. (2025). A Novel Polysilicon-Fill-Strengthened Etch-Through 3D Trench Electrode Detector: Fabrication Methods and Electrical Property Simulations. Micromachines, 16(8), 912. https://doi.org/10.3390/mi16080912
Vancouver
Zhu X, Li Z, Liu Z, Long T, Zhao J, Li X, et al. A Novel Polysilicon-Fill-Strengthened Etch-Through 3D Trench Electrode Detector: Fabrication Methods and Electrical Property Simulations. Micromachines. 2025;16(8):912. doi:10.3390/mi16080912
BibTeX
@article{Zhu2025,
author = {Zhu, Xuran and Li, Zheng and Liu, Zhiyu and Long, Tao and Zhao, Jun and Li, Xinqing and Liu, Manwen and Wang, Meishan},
title = {A Novel Polysilicon-Fill-Strengthened Etch-Through 3D Trench Electrode Detector: Fabrication Methods and Electrical Property Simulations},
journal = {Micromachines},
year = {2025},
volume = {16},
number = {8},
pages = {912},
doi = {10.3390/mi16080912}
}
EUVIMED