Fachartikel in der Zeitschrift Micromachines, online erschienen am 18.08.2024. Verfasst von Jiaqi Miao und 7 weiteren Autor:innen. Beteiligte Einrichtung: College of Mechanical Engineering, Shandong University of Technology, Zibo 255000, China. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Taishan Scholars Program of Shandong Province, Natural Science Foundation of Shandong Province, Natural Science Foundation of Shandong Province, China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This article proposes a low cross-axis sensitivity resonant MEMS(Micro-Electro-Mechanical Systems) accelerometer that is optimized based on the BP and NSGA-II algorithms. When resonant accelerometers are used in seismic monitoring, automotive safety systems, and navigation applications, high immunity and low cross-axis sensitivity are required. To improve the high immunity of the accelerometer, a coupling structure is introduced. This structure effectively separates the symmetric and antisymmetric mode frequencies of the DETF resonator and prevents mode coupling. To obtain higher detection accuracy and low cross-axis sensitivity, a decoupling structure is introduced. To find the optimal dimensional parameters of the decoupled structure, the BP and NSGA-II algorithms are used to optimize the dimensional parameters of the decoupled structure. The optimized decoupled structure has an axial stiffness of 6032.21 N/m and a transverse stiffness of 6.29 N/m. The finite element analysis results show that the sensitivity of the accelerometer is 59.1 Hz/g (Y-axis) and 59 Hz/g (X-axis). Cross-axis sensitivity is 0.508% (Y-axis) and 0.339% (X-axis), which is significantly lower than most resonant accelerometers. The coupling structure and optimization method proposed in this paper provide a new solution for designing resonant accelerometers with high interference immunity and low cross-axis sensitivity.

Schlagwörter

Stichwörter der Autor:innen

BP and NSGA-II algorithmMEMS resonant accelerometercross-axis sensitivitymulti-objective optimization

Autor:innen und Institutionen

  • College of Mechanical Engineering, Shandong University of Technology, Zibo 255000, China.

Förderung

  • Taishan Scholars Program of Shandong Province
  • Natural Science Foundation of Shandong Province
  • Natural Science Foundation of Shandong Province, China
  • Shandong Provincial Key Laboratory of Precision Manufacturing and Nontraditional Machining

Zitieren

APA

Miao, J., Li, P., Lv, M., Nie, S., Liu, Y., Liang, R., Ma, W., & Zhuang, X. (2024). Resonant MEMS Accelerometer with Low Cross-Axis Sensitivity—Optimized Based on BP and NSGA-II Algorithms. Micromachines, 15(8), 1049. https://doi.org/10.3390/mi15081049

Vancouver

Miao J, Li P, Lv M, Nie S, Liu Y, Liang R, et al. Resonant MEMS Accelerometer with Low Cross-Axis Sensitivity—Optimized Based on BP and NSGA-II Algorithms. Micromachines. 2024;15(8):1049. doi:10.3390/mi15081049

BibTeX
@article{Miao2024,
  author = {Miao, Jiaqi and Li, Pinghua and Lv, Mingchen and Nie, Suzhen and Liu, Yang and Liang, Ruimei and Ma, Weijiang and Zhuang, Xuye},
  title = {Resonant MEMS Accelerometer with Low Cross-Axis Sensitivity—Optimized Based on BP and NSGA-II Algorithms},
  journal = {Micromachines},
  year = {2024},
  volume = {15},
  number = {8},
  pages = {1049},
  doi = {10.3390/mi15081049}
}
Kostenlos starten →