Espial: Electrochemical Soil pH Sensor for In Situ Real-Time Monitoring
Micromachines · 30.11.2023 · 14 (12) · 2188
DOI: 10.3390/mi14122188 ↗Kurz gefasst
Fachartikel in der Zeitschrift Micromachines, online erschienen am 30.11.2023. Verfasst von Mohammed A Eldeeb und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Bioengineering, University of Texas at Dallas, Richardson, TX 75080, USA. Die Arbeit wurde bisher 28-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Soil in Formation (SiF), Soil In Formation, PBC (SiF).
Abstract (Originalsprache)
We present a first-of-its-kind electrochemical sensor that demonstrates direct real-time continuous soil pH measurement without any soil pre-treatment. The sensor functionality, performance, and in-soil dynamics have been reported. The sensor coating is a composite matrix of alizarin and Nafion applied by drop casting onto the working electrode. Electrochemical impedance spectroscopy (EIS) and squarewave voltammetry (SWV) studies were conducted to demonstrate the functionality of each method in accurately detecting soil pH. The studies were conducted on three different soil textures (clay, sandy loam, and loamy clay) to cover the range of the soil texture triangle. Squarewave voltammetry showed pH-dependent responses regardless of soil texture (while electrochemical impedance spectroscopy’s pH detection range was limited and dependent on soil texture). The linear models showed a sensitivity range from −50 mV/pH up to −66 mV/pH with R2 > 0.97 for the various soil textures in the pH range 3–9. The validation of the sensor showed less than a 10% error rate between the measured pH and reference pH for multiple different soil textures including ones that were not used in the calibration of the sensor. A 7-day in situ soil study showed the capability of the sensor to measure soil pH in a temporally dynamic manner with an error rate of less than 10%. The test was conducted using acidic and alkaline soils with pH values of 5.05 and 8.36, respectively.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Bioengineering, University of Texas at Dallas, Richardson, TX 75080, USA.
- EnLiSense LLC, Allen, TX 75013, USA.
ORCID-Profile: Vikram Narayanan Dhamu, Anirban Paul, Shalini Prasad
Förderung
- Soil in Formation (SiF)
- Soil In Formation, PBC (SiF)
Zitieren
APA
Eldeeb, M. A., Dhamu, V. N., Paul, A., Muthukumar, S., & Prasad, S. (2023). Espial: Electrochemical Soil pH Sensor for In Situ Real-Time Monitoring. Micromachines, 14(12), 2188. https://doi.org/10.3390/mi14122188
Vancouver
Eldeeb MA, Dhamu VN, Paul A, Muthukumar S, Prasad S. Espial: Electrochemical Soil pH Sensor for In Situ Real-Time Monitoring. Micromachines. 2023;14(12):2188. doi:10.3390/mi14122188
BibTeX
@article{Eldeeb2023,
author = {Eldeeb, Mohammed A and Dhamu, Vikram Narayanan and Paul, Anirban and Muthukumar, Sriram and Prasad, Shalini},
title = {Espial: Electrochemical Soil pH Sensor for In Situ Real-Time Monitoring},
journal = {Micromachines},
year = {2023},
volume = {14},
number = {12},
pages = {2188},
doi = {10.3390/mi14122188}
}
EUVIMED