EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Wireless IrO 2 Electrochemical Sensor System for Real-Time pH Monitoring in Microliter Volumes

Sekar Madhu iD, Sriramprabha Ramasamy iD, Jungil Choi iD

ACS Measurement Science Au · 18.02.2026 · 6 (1) · 238-248

DOI: 10.1021/acsmeasuresciau.5c00181 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Measurement Science Au, online erschienen am 06.01.2026. Verfasst von Sekar Madhu und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, Ajou University, Suwon 16499, Republic of Korea. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 59 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Ministry of Science and ICT, South Korea.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate pH measurement in microliter volumes is essential for real-time chemical and biological analysis, underpinning modern portable and point-of-care diagnostics. Here, we present a wireless electrochemical pH sensor system based on nanostructured iridium oxide (IrO2) electrodeposited onto electron-beam-evaporated, photolithographically patterned gold electrodes (EBLG) and integrated with a low-power Bluetooth potentiostat for continuous, real-time pH monitoring. FESEM, Raman, and XPS confirm uniform spherical IrO2 nanostructures with mixed Ir3+/Ir4+ states that are conducive to potentiometric transduction. The IrO2/EBLG sensor exhibited near-Nernstian sensitivity (69.7 mV/pH) across a pH range of 2-9, a fast step response (∼10 s), negligible hysteresis during bidirectional cycling, and exceptionally low potential drift (∼0.12-0.28 mV/h over 12 h). It demonstrates high selectivity toward H+ ions against common physiological interferences with excellent reproducibility and robust long-term stability. The hand-held module wirelessly streams real-time potential data to a smartphone, enabling accurate pH quantification in microliter-scale biological, food, and environmental samples. Measurements showed strong agreement with a commercial microelectrode pH meter, with no statistically significant difference (p > 0.05; Bland-Altman and paired t-test). Overall, the IrO2/EBLG platform combines miniaturization, stability, and wireless functionality, offering a reliable and scalable solution for decentralized pH sensing and paving a promising route toward future wearable, field-deployable, and environmental pH monitoring systems.

Schlagwörter

Stichwörter der Autor:innen

iridium oxidemicroliter volumeminiaturized sensingpH sensorpoint-of-carewireless diagnostics

Autor:innen und Institutionen

  • Department of Mechanical Engineering, Ajou University, Suwon 16499, Republic of Korea.

ORCID-Profile: Sekar Madhu, Sriramprabha Ramasamy, Jungil Choi

Förderung

  • Ministry of Science and ICT, South Korea

Zitieren

APA

Madhu, S., Ramasamy, S., & Choi, J. (2026). Wireless IrO 2 Electrochemical Sensor System for Real-Time pH Monitoring in Microliter Volumes. ACS Measurement Science Au, 6(1), 238-248. https://doi.org/10.1021/acsmeasuresciau.5c00181

Vancouver

Madhu S, Ramasamy S, Choi J. Wireless IrO 2 Electrochemical Sensor System for Real-Time pH Monitoring in Microliter Volumes. ACS Measurement Science Au. 2026;6(1):238-248. doi:10.1021/acsmeasuresciau.5c00181

BibTeX
@article{Madhu2026,
  author = {Madhu, Sekar and Ramasamy, Sriramprabha and Choi, Jungil},
  title = {Wireless IrO 2 Electrochemical Sensor System for Real-Time pH Monitoring in Microliter Volumes},
  journal = {ACS Measurement Science Au},
  year = {2026},
  volume = {6},
  number = {1},
  pages = {238--248},
  doi = {10.1021/acsmeasuresciau.5c00181}
}
Kostenlos starten →