EUVIMEDScopri EUVIMED
Open access · CC BY 4.0

Numerical Model Validation of the Blood Flow through a Microchannel Hyperbolic Contraction

Filipe Barbosa iD, Jorge Dueñas-Pamplona iD, Cristiano S Abreu iD, Mónica S N Oliveira, Rui A Lima iD

Micromachines · 2023-09-30 · 14 (10) · 1886

DOI: 10.3390/mi14101886 ↗

At a glance

Journal article in Micromachines, published online on 2023-09-30. Written by Filipe Barbosa and 4 co-authors. Institution: Mechanical Engineering and Resource Sustainability Center (METRICS), University of Minho, 4800-058 Guimarães, Portugal. Cited 7 times so far (Crossref); 38 references. The full text is freely available (open access, CC BY 4.0). Funded by: Fundação para a Ciência e Tecnologia, Scientific Research and Technological Development Projects, R&D Units Project Scope and by national funds through FCT/MCTES (PIDDAC).

AbstractSubjectsDati bibliograficiCiteRelated studies

Abstract (original language)

A computational fluid dynamics (CFD) model of blood flow through hyperbolic contraction with a discrete phase model (DPM) was experimentally validated. For this purpose, the positions and velocities of red blood cells (RBCs) flowing in a microchannel with hyperbolic contraction were experimentally assessed using image analysis techniques, and were subsequently compared with the numerical results. The numerically and experimentally obtained velocity fields were in good agreement, with errors smaller than 10%. Additionally, a nearly constant strain rate was observed in the contraction region, which can be attributed to the quasilinear increase in the velocity along the hyperbolic contraction. Therefore, the numerical technique used was validated due to the close similarity between the numerically and experimentally obtained results. The tested CFD model can be used to optimize the microchannel design by minimizing the need to fabricate prototypes and evaluate them experimentally.

Subjects

Author keywords

blood flowexperimental validationhyperbolic contractionmicrofluidicsnumerical modeling

Authors and institutions

  • Mechanical Engineering and Resource Sustainability Center (METRICS), University of Minho, 4800-058 Guimarães, Portugal.
  • Departamento de Ingeniería Energética, Universidad Politécnica de Madrid, 28040 Madrid, Spain.
  • Center for MicroElectromechanical Systems (CMEMS-UMinho), University of Minho, 4800-058 Guimarães, Portugal.
  • LABBELS-Associate Laboratory, 4710-057 Braga, Portugal.
  • Physics Department, Porto Superior Engineering Institute, ISEP, 4200-072 Porto, Portugal.
  • James Weir Fluids Laboratory, Department of Mechanical and Aerospace Engineering, University of Strathclyde, Glasgow G1 1XJ, UK.

ORCID profiles: Filipe Barbosa, Jorge Dueñas-Pamplona, Cristiano S Abreu, Rui A Lima

Funding

  • Fundação para a Ciência e Tecnologia
  • Scientific Research and Technological Development Projects
  • R&D Units Project Scope and by national funds through FCT/MCTES (PIDDAC)

Cite

APA

Barbosa, F., Dueñas-Pamplona, J., Abreu, C. S., Oliveira, M. S. N., & Lima, R. A. (2023). Numerical Model Validation of the Blood Flow through a Microchannel Hyperbolic Contraction. Micromachines, 14(10), 1886. https://doi.org/10.3390/mi14101886

Vancouver

Barbosa F, Dueñas-Pamplona J, Abreu CS, Oliveira MSN, Lima RA. Numerical Model Validation of the Blood Flow through a Microchannel Hyperbolic Contraction. Micromachines. 2023;14(10):1886. doi:10.3390/mi14101886

BibTeX
@article{Barbosa2023,
  author = {Barbosa, Filipe and Dueñas-Pamplona, Jorge and Abreu, Cristiano S and Oliveira, Mónica S N and Lima, Rui A},
  title = {Numerical Model Validation of the Blood Flow through a Microchannel Hyperbolic Contraction},
  journal = {Micromachines},
  year = {2023},
  volume = {14},
  number = {10},
  pages = {1886},
  doi = {10.3390/mi14101886}
}