Numerical Model Validation of the Blood Flow through a Microchannel Hyperbolic Contraction
Micromachines · 30.09.2023 · 14 (10) · 1886
DOI: 10.3390/mi14101886 ↗Kurz gefasst
Fachartikel in der Zeitschrift Micromachines, online erschienen am 30.09.2023. Verfasst von Filipe Barbosa und 4 weiteren Autor:innen. Beteiligte Einrichtung: Mechanical Engineering and Resource Sustainability Center (METRICS), University of Minho, 4800-058 Guimarães, Portugal. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fundação para a Ciência e Tecnologia, Scientific Research and Technological Development Projects, R&D Units Project Scope and by national funds through FCT/MCTES (PIDDAC).
Abstract (Originalsprache)
A computational fluid dynamics (CFD) model of blood flow through hyperbolic contraction with a discrete phase model (DPM) was experimentally validated. For this purpose, the positions and velocities of red blood cells (RBCs) flowing in a microchannel with hyperbolic contraction were experimentally assessed using image analysis techniques, and were subsequently compared with the numerical results. The numerically and experimentally obtained velocity fields were in good agreement, with errors smaller than 10%. Additionally, a nearly constant strain rate was observed in the contraction region, which can be attributed to the quasilinear increase in the velocity along the hyperbolic contraction. Therefore, the numerical technique used was validated due to the close similarity between the numerically and experimentally obtained results. The tested CFD model can be used to optimize the microchannel design by minimizing the need to fabricate prototypes and evaluate them experimentally.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Mechanical Engineering and Resource Sustainability Center (METRICS), University of Minho, 4800-058 Guimarães, Portugal.
- Departamento de Ingeniería Energética, Universidad Politécnica de Madrid, 28040 Madrid, Spain.
- Center for MicroElectromechanical Systems (CMEMS-UMinho), University of Minho, 4800-058 Guimarães, Portugal.
- LABBELS-Associate Laboratory, 4710-057 Braga, Portugal.
- Physics Department, Porto Superior Engineering Institute, ISEP, 4200-072 Porto, Portugal.
- James Weir Fluids Laboratory, Department of Mechanical and Aerospace Engineering, University of Strathclyde, Glasgow G1 1XJ, UK.
ORCID-Profile: Filipe Barbosa, Jorge Dueñas-Pamplona, Cristiano S Abreu, Rui A Lima
Förderung
- Fundação para a Ciência e Tecnologia
- Scientific Research and Technological Development Projects
- R&D Units Project Scope and by national funds through FCT/MCTES (PIDDAC)
Zitieren
APA
Barbosa, F., Dueñas-Pamplona, J., Abreu, C. S., Oliveira, M. S. N., & Lima, R. A. (2023). Numerical Model Validation of the Blood Flow through a Microchannel Hyperbolic Contraction. Micromachines, 14(10), 1886. https://doi.org/10.3390/mi14101886
Vancouver
Barbosa F, Dueñas-Pamplona J, Abreu CS, Oliveira MSN, Lima RA. Numerical Model Validation of the Blood Flow through a Microchannel Hyperbolic Contraction. Micromachines. 2023;14(10):1886. doi:10.3390/mi14101886
BibTeX
@article{Barbosa2023,
author = {Barbosa, Filipe and Dueñas-Pamplona, Jorge and Abreu, Cristiano S and Oliveira, Mónica S N and Lima, Rui A},
title = {Numerical Model Validation of the Blood Flow through a Microchannel Hyperbolic Contraction},
journal = {Micromachines},
year = {2023},
volume = {14},
number = {10},
pages = {1886},
doi = {10.3390/mi14101886}
}
EUVIMED