EUVIMEDOpdag EUVIMED
ÜbersichtsarbeitOpen access · CC BY 4.0

Exploring Copper Oxide and Copper Sulfide for Non-Enzymatic Glucose Sensors: Current Progress and Future Directions

Nonkululeko Miya, Lerato F Eugeni Machogo-Phao iD, Bulelwa Ntsendwana

Micromachines · 2023-09-27 · 14 (10) · 1849

DOI: 10.3390/mi14101849 ↗

At a glance

Übersichtsarbeit in Micromachines, published online on 2023-09-27. Written by Nonkululeko Miya and 2 co-authors. Institution: DSI/Mintek Nanotechnology Innovation Centre, Advanced Materials Division, Mintek, Private Bag X3015, Randburg 2125, South Africa. Cited 22 times so far (Crossref); 118 references. The full text is freely available (open access, CC BY 4.0). Funded by: Department of Science and Innovation/Nanotechnology Innovation Centre.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Millions of people worldwide are affected by diabetes, a chronic disease that continuously grows due to abnormal glucose concentration levels present in the blood. Monitoring blood glucose concentrations is therefore an essential diabetes indicator to aid in the management of the disease. Enzymatic electrochemical glucose sensors presently account for the bulk of glucose sensors on the market. However, their disadvantages are that they are expensive and dependent on environmental conditions, hence affecting their performance and sensitivity. To meet the increasing demand, non-enzymatic glucose sensors based on chemically modified electrodes for the direct electrocatalytic oxidation of glucose are a good alternative to the costly enzymatic-based sensors currently on the market, and the research thereof continues to grow. Nanotechnology-based biosensors have been explored for their electronic and mechanical properties, resulting in enhanced biological signaling through the direct oxidation of glucose. Copper oxide and copper sulfide exhibit attractive attributes for sensor applications, due to their non-toxic nature, abundance, and unique properties. Thus, in this review, copper oxide and copper sulfide-based materials are evaluated based on their chemical structure, morphology, and fast electron mobility as suitable electrode materials for non-enzymatic glucose sensors. The review highlights the present challenges of non-enzymatic glucose sensors that have limited their deployment into the market.

Subjects

Author keywords

copper oxidecopper sulfideelectrochemicalglucosenon-enzymaticsensor

Authors and institutions

  • DSI/Mintek Nanotechnology Innovation Centre, Advanced Materials Division, Mintek, Private Bag X3015, Randburg 2125, South Africa.

ORCID profiles: Lerato F Eugeni Machogo-Phao

Funding

  • Department of Science and Innovation/Nanotechnology Innovation Centre

Cite

APA

Miya, N., Machogo-Phao, L. F. E., & Ntsendwana, B. (2023). Exploring Copper Oxide and Copper Sulfide for Non-Enzymatic Glucose Sensors: Current Progress and Future Directions. Micromachines, 14(10), 1849. https://doi.org/10.3390/mi14101849

Vancouver

Miya N, Machogo-Phao LFE, Ntsendwana B. Exploring Copper Oxide and Copper Sulfide for Non-Enzymatic Glucose Sensors: Current Progress and Future Directions. Micromachines. 2023;14(10):1849. doi:10.3390/mi14101849

BibTeX
@article{Miya2023,
  author = {Miya, Nonkululeko and Machogo-Phao, Lerato F Eugeni and Ntsendwana, Bulelwa},
  title = {Exploring Copper Oxide and Copper Sulfide for Non-Enzymatic Glucose Sensors: Current Progress and Future Directions},
  journal = {Micromachines},
  year = {2023},
  volume = {14},
  number = {10},
  pages = {1849},
  doi = {10.3390/mi14101849}
}
Start for free →