EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Simultaneous Hydrostatic and Compressive Loading System for Mimicking the Mechanical Environment of Living Cartilage Tissue

Minki Chang iD, Yosuke Takahashi, Kyosuke Miyahira, Yuma Omuro, Kevin Montagne, Ryusei Yamada, Junki Gondo, Yu Kambe, Masashi Yasuno, Noriyasu Masumoto, Takashi Ushida, Katsuko S Furukawa

Micromachines · 18.08.2023 · 14 (8) · 1632

DOI: 10.3390/mi14081632 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Micromachines, online erschienen am 18.08.2023. Verfasst von Minki Chang und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Bioengineering, Graduate School of Engineering, University of Tokyo, Tokyo 113-8656, Japan. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Society for the Promotion of Science, AMADA Foundation, JKA.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In vivo, articular cartilage tissue is surrounded by a cartilage membrane, and hydrostatic pressure (HP) and compressive strain increase simultaneously with the compressive stress. However, it has been impossible to investigate the effects of simultaneous loading in vitro. In this study, a bioreactor capable of applying compressive stress under HP was developed to reproduce ex vivo the same physical loading environment found in cartilage. First, a HP stimulation unit was constructed to apply a cyclic HP pressure-resistant chamber by controlling a pump and valve. A compression-loading mechanism that can apply compressive stress using an electromagnetic force was implemented in the chamber. The synchronization between the compression and HP units was evaluated, and the stimulation parameters were quantitatively evaluated. Physiological HP and compressive strain were applied to the chondrocytes encapsulated in alginate and gelatin gels after applying high HP at 25 MPa, which induced damage to the chondrocytes. It was found that compressive stimulation increased the expression of genes related to osteoarthritis. Furthermore, the simultaneous application of compressive strain and HP, which is similar to the physiological environment in cartilage, had an inhibitory effect on the expression of genes related to osteoarthritis. HP alone also suppressed the expression of osteoarthritis-related genes. Therefore, the simultaneous hydrostatic and compressive stress-loading device developed to simulate the mechanical environment in vivo may be an important tool for elucidating the mechanisms of disease onset and homeostasis in cartilage.

Schlagwörter

Stichwörter der Autor:innen

articular cartilagebioreactormechanical stimulation

Autor:innen und Institutionen

  • Department of Bioengineering, Graduate School of Engineering, University of Tokyo, Tokyo 113-8656, Japan.
  • Department of Mechanical Engineering, Graduate School of Engineering, University of Tokyo, Tokyo 113-8656, Japan.
  • Department of Mechanical Engineering, Faculty of Fundamental Engineering, Nippon Institute of Technology, Saitama 345-8501, Japan.

ORCID-Profile: Minki Chang

Förderung

  • Japan Society for the Promotion of Science
  • AMADA Foundation
  • JKA

Zitieren

APA

Chang, M., Takahashi, Y., Miyahira, K., Omuro, Y., Montagne, K., Yamada, R., Gondo, J., Kambe, Y., Yasuno, M., Masumoto, N., Ushida, T., & Furukawa, K. S. (2023). Simultaneous Hydrostatic and Compressive Loading System for Mimicking the Mechanical Environment of Living Cartilage Tissue. Micromachines, 14(8), 1632. https://doi.org/10.3390/mi14081632

Vancouver

Chang M, Takahashi Y, Miyahira K, Omuro Y, Montagne K, Yamada R, et al. Simultaneous Hydrostatic and Compressive Loading System for Mimicking the Mechanical Environment of Living Cartilage Tissue. Micromachines. 2023;14(8):1632. doi:10.3390/mi14081632

BibTeX
@article{Chang2023,
  author = {Chang, Minki and Takahashi, Yosuke and Miyahira, Kyosuke and Omuro, Yuma and Montagne, Kevin and Yamada, Ryusei and Gondo, Junki and Kambe, Yu and Yasuno, Masashi and Masumoto, Noriyasu and Ushida, Takashi and Furukawa, Katsuko S},
  title = {Simultaneous Hydrostatic and Compressive Loading System for Mimicking the Mechanical Environment of Living Cartilage Tissue},
  journal = {Micromachines},
  year = {2023},
  volume = {14},
  number = {8},
  pages = {1632},
  doi = {10.3390/mi14081632}
}
Kostenlos starten →