Performance Testing of Micro-Electromechanical Acceleration Sensors for Pavement Vibration Monitoring

Zhoujing Ye iD, Ya Wei, Biyu Yang, Linbing Wang

Micromachines · 07.01.2023 · 14 (1) · 153

DOI: 10.3390/mi14010153 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Micromachines, online erschienen am 07.01.2023. Verfasst von Zhoujing Ye und 3 weiteren Autor:innen. Beteiligte Einrichtung: National Center for Materials Service Safety, University of Science and Technology Beijing, Beijing 100083, China. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the National Natural Science Foundation of China, the National Key Research and Development Plan, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Pavement vibration monitoring under vehicle loads can be used to acquire traffic information and assess the health of pavement structures, which contributes to smart road construction. However, the effectiveness of monitoring is closely related to sensor performance. In order to select the suitable acceleration sensor for pavement vibration monitoring, a printed circuit board (PCB) with three MEMS (micro-electromechanical) accelerometer chips (VS1002, MS9001, and ADXL355) is developed in this paper, and the circuit design and software development of the PCB are completed. The experimental design and comparative testing of the sensing performance of the three MEMS accelerometer chips, in terms of sensitivity, linearity, noise, resolution, frequency response, and temperature drift, were conducted. The results show that the dynamic and static calibration methods of the sensitivity test had similar results. The influence of gravitational acceleration should be considered when selecting the range of the accelerometer to avoid the phenomenon of over-range. The VS1002 has the highest sensitivity and resolution under 3.3 V standard voltage supply, as well as the best overall performance. The ADXL355 is virtually temperature-independent in the temperature range from −20 °C to 60 °C, while the voltage reference values output by the VS1002 and MS9001 vary linearly with temperature. This research contributes to the development of acceleration sensors with high precision and long life for pavement vibration monitoring.

Schlagwörter

Stichwörter der Autor:innen

MEMS accelerometercomparative evaluationpavement vibrationsensing performancesmart road

Autor:innen und Institutionen

  • National Center for Materials Service Safety, University of Science and Technology Beijing, Beijing 100083, China.
  • Department of Civil Engineering, Tsinghua University, Beijing 100084, China.
  • Zhaotong Highway Investment Development Co., Ltd., Zhaotong 657099, China.
  • Highway School, Chang'an University, Xi'an 710054, China.
  • School of Environmental, Civil, Agricultural and Mechanical Engineering, University of Georgia, Athens, GA 30602, USA.

ORCID-Profile: Zhoujing Ye

Förderung

  • the National Natural Science Foundation of China
  • the National Key Research and Development Plan
  • National Natural Science Foundation of China
  • National Key Research and Development Plan
  • Technology Innovation and Demonstration Project of the Department of Transport of Yunnan Province (2021) No. 25

Zitieren

APA

Ye, Z., Wei, Y., Yang, B., & Wang, L. (2023). Performance Testing of Micro-Electromechanical Acceleration Sensors for Pavement Vibration Monitoring. Micromachines, 14(1), 153. https://doi.org/10.3390/mi14010153

Vancouver

Ye Z, Wei Y, Yang B, Wang L. Performance Testing of Micro-Electromechanical Acceleration Sensors for Pavement Vibration Monitoring. Micromachines. 2023;14(1):153. doi:10.3390/mi14010153

BibTeX
@article{Ye2023,
  author = {Ye, Zhoujing and Wei, Ya and Yang, Biyu and Wang, Linbing},
  title = {Performance Testing of Micro-Electromechanical Acceleration Sensors for Pavement Vibration Monitoring},
  journal = {Micromachines},
  year = {2023},
  volume = {14},
  number = {1},
  pages = {153},
  doi = {10.3390/mi14010153}
}