Evaluation of Lattice Structures for Medical Implants: A Study on the Mechanical Properties of Various Unit Cell Types
Metals · 02.07.2024 · 14 (7) · 780
DOI: 10.3390/met14070780 ↗Kurz gefasst
Fachartikel in der Zeitschrift Metals, online erschienen am 02.07.2024. Verfasst von Pedro Nogueira und 7 weiteren Autor:innen. Die Arbeit wurde bisher 27-mal zitiert (Crossref) und nennt 56 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fundação para a Ciência e a Tecnologia (FCT), IDMEC under LAETA Base Funding, LAETA Programatic Funding.
Abstract (Originalsprache)
Lattice structures are a prime candidate for applications in the medical implant industry due to their versatile mechanical behaviour, which can be tailored to meet specific patient needs and reduce stress shielding, while enabling the natural flow of body fluids. In this work, the mechanical properties of metallic lattices made of five different unit cell types, Cubic (C), Truncated Octahedron (TO), Truncated Cubic (TC), Rhombicuboctahedron (RCO), and Rhombitruncated Cuboctahedron (RTCO), were evaluated under uniaxial compression at three different relative densities, 5%, 15%, and 45%. The evaluation was experimental, and it was compared with previous and new finite element simulations. Specimens for the experimental tests were fabricated in stainless steel 316L by laser powder bed fusion, and stress–strain curves were obtained for the different lattices. The combination of the test results with a critical interpretation of the deformation mechanisms allowed us to confirm that two unit cell types, TO and RTCO, are stable for the whole range of relative densities evaluated. The other three unit cells exhibit more unpredictable behaviour, either due to manufacturing defects or limitations, or because their unstable compression behaviour leads to bucking. For these reasons, TO and RTCO unit cell types are mechanically more adequate for applications in the medical implant industry.
Förderung
- Fundação para a Ciência e a Tecnologia (FCT)
- IDMEC under LAETA Base Funding
- LAETA Programatic Funding
- CeFEMA project
Zitieren
APA
Nogueira, P., Lopes, P., Oliveira, L., Alves, J. L., Magrinho, J. P. G., Deus, A. M. D., Vaz, M. F., & Silva, M. B. (2024). Evaluation of Lattice Structures for Medical Implants: A Study on the Mechanical Properties of Various Unit Cell Types. Metals, 14(7), 780. https://doi.org/10.3390/met14070780
Vancouver
Nogueira P, Lopes P, Oliveira L, Alves JL, Magrinho JPG, Deus AMD, et al. Evaluation of Lattice Structures for Medical Implants: A Study on the Mechanical Properties of Various Unit Cell Types. Metals. 2024;14(7):780. doi:10.3390/met14070780
BibTeX
@article{Nogueira2024,
author = {Nogueira, Pedro and Lopes, Pedro and Oliveira, Luís and Alves, Jorge L. and Magrinho, João P. G. and Deus, Augusto Moita de and Vaz, M. Fátima and Silva, M. Beatriz},
title = {Evaluation of Lattice Structures for Medical Implants: A Study on the Mechanical Properties of Various Unit Cell Types},
journal = {Metals},
year = {2024},
volume = {14},
number = {7},
pages = {780},
doi = {10.3390/met14070780}
}
EUVIMED