Kurz gefasst

Fachartikel in der Zeitschrift Membranes, online erschienen am 19.11.2026. Verfasst von Gorazd Bombek und 3 weiteren Autor:innen. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Slovenian Research Agency.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Understanding how a filter membrane affects both the steady flow and pressure transients of intermittent dead-end microfiltration systems is important for their design and operation. This study experimentally investigates the hydraulic resistance and pressure-wave response of a single-membrane filter cartridge using distilled water. The experiments were performed with intact membranes and with membranes removed to assess their contribution relative to the filter housing and connecting elements. The mass flow and pressure drop were measured at different supply pressures, while simultaneous upstream and downstream pressure measurements captured the reproducible transients generated by electropneumatic valve actuation. A frequency analysis and comparisons between experiments with and without flow were used to examine pressure-wave transmission and distinguish flow-related oscillations from those associated with valve actuation and the experimental setup. The estimated resistance of the membrane was approximately 5–15 times that of the filter housing and associated connectors. The membrane attenuated pressure oscillations, introducing an additional transmission delay of approximately 2–3 ms, with the measured signals indicating low-pass filtering behaviour. These findings reveal that the membrane influences both the hydraulic losses and dynamic response of the filtration system, providing experimental data for transient model validation and the assessment of intermittent filtration processes. Some kind of resonance at 10 Hz was observed at a fluid pressure of 1 bar.

Förderung

  • Slovenian Research Agency

Zitieren

APA

Bombek, G., Jernejc, T., Lešnik, L., & Ramšak, M. (2026). The Influence of a Dead-End Filter Membrane on Flow Properties. Membranes, 16(11), 393. https://doi.org/10.3390/membranes16110393

Vancouver

Bombek G, Jernejc T, Lešnik L, Ramšak M. The Influence of a Dead-End Filter Membrane on Flow Properties. Membranes. 2026;16(11):393. doi:10.3390/membranes16110393

BibTeX
@article{Bombek2026,
  author = {Bombek, Gorazd and Jernejc, Tilen and Lešnik, Luka and Ramšak, Matjaž},
  title = {The Influence of a Dead-End Filter Membrane on Flow Properties},
  journal = {Membranes},
  year = {2026},
  volume = {16},
  number = {11},
  pages = {393},
  doi = {10.3390/membranes16110393}
}
Kostenlos starten →