Gait Analysis Study Comparing Unicompartmental vs. Total Knee Arthroplasty: Differences in Knee Kinematics
Medicina · 28.03.2026 · 62 (4) · 648
DOI: 10.3390/medicina62040648 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Medicina, online erschienen am 28.03.2026. Verfasst von Vittorio Castoldi und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedics and Traumatology, University of Turin, 10126 Turin, Italy. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Gait Analysis. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Gait analysis study comparing unicompartmental vs. total knee arthroplasty, differences in knee kinematics: a retrospective cohort study. Background and Objectives: Total knee arthroplasty (TKA) is an effective treatment for advanced knee osteoarthritis, although functional outcomes may remain suboptimal in many patients. Unicompartmental knee arthroplasty (UKA) often provides better functional recovery but shows lower long-term implant survival. Recently, personalized TKA approaches have been developed to improve kinematic restoration and patient satisfaction. This study aimed to compare knee kinematics among patients who underwent personalized TKA, medial UKA, and healthy controls. Materials and Methods: This retrospective cohort study included 9 patients treated with robotic-assisted personalized TKA, 9 patients treated with medial UKA, and 9 healthy controls matched for age, sex, and BMI. Inclusion criteria were age 60–80 years, Kellgren–Lawrence grade III–IV, a minimum follow-up of 12 months, deviation from neutral HKA < 15°, healthy contralateral knee, and high postoperative functional scores. Exclusion criteria included valgus knees (HKA > 180°), postoperative complications, and neuromotor disorders. In the TKA group, a Medial Congruent implant was implanted with ROSA robotic assistance using a restricted kinematic alignment (±5° HKA) and asymmetric intercompartmental balancing. In the UKA group, a fixed-bearing medial implant (Physica ZUK) was used. Gait analysis was performed on a markerless instrumented treadmill (WalkerView™; Dalmine, Italy). Differences between groups were analyzed using one-way ANOVA and Tukey’s post-hoc test (p < 0.05).
Results
UKA patients walked with a stiffer knee during stance. Knee range of motion during stance increased from UKA (6.3° ± 7.2°) to TKA (13.6° ± 8.8°, p = 0.045) and to controls (16.6° ± 4.5°, p = 0.02). During loading response, UKA patients showed lower flexion (10.2° ± 6.1°) than TKA (19.4° ± 7.9°, p = 0.049) and controls (19.6° ± 2.8°, p = 0.004). Knee flexion during swing was comparable between UKA and TKA.
Conclusions
UKA patients demonstrated reduced knee flexion during early stance compared with robotic-assisted TKA and healthy controls. The observed differences may reflect multiple factors, including surgical technique, implant design, and patient-related characteristics. Because preoperative functional data were not available, potential selection bias cannot be excluded. These findings should be interpreted cautiously and warrant confirmation in larger prospective studies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopedics and Traumatology, University of Turin, 10126 Turin, Italy.
- Department of Orthpaedic Surgery, Sudtiroler Sanitatsbertrieb, 39042 Brixen, Italy.
- Dipartimento di Medicina Clinica, Sanità Pubblica, Scienze della Vita e dell'Ambiente, Università degli Studi dell'Aquila, 67100 L'Aquila, Italy.
- Institute of Biomechanics, Paracelsus Medical University (PMU), 5020 Salzburg, Austria.
- Department of Orthopedic Surgery, Stanford University School of Medicine, Redwood City, CA 94063, USA.
ORCID-Profile: Vittorio Castoldi, Andrea Giordano Salvi, Giuseppe Petralia, Giuseppe Aloisi, Pieralberto Valpiana, Alessandro Aprato, Alessandro Massè, Pier Francesco Indelli
Zitieren
APA
Castoldi, V., Salvi, A. G., Petralia, G., Aloisi, G., Valpiana, P., Aprato, A., Massè, A., Indelli, P. F., & Risitano, S. (2026). Gait Analysis Study Comparing Unicompartmental vs. Total Knee Arthroplasty: Differences in Knee Kinematics. Medicina, 62(4), 648. https://doi.org/10.3390/medicina62040648
Vancouver
Castoldi V, Salvi AG, Petralia G, Aloisi G, Valpiana P, Aprato A, et al. Gait Analysis Study Comparing Unicompartmental vs. Total Knee Arthroplasty: Differences in Knee Kinematics. Medicina. 2026;62(4):648. doi:10.3390/medicina62040648
BibTeX
@article{Castoldi2026,
author = {Castoldi, Vittorio and Salvi, Andrea Giordano and Petralia, Giuseppe and Aloisi, Giuseppe and Valpiana, Pieralberto and Aprato, Alessandro and Massè, Alessandro and Indelli, Pier Francesco and Risitano, Salvatore},
title = {Gait Analysis Study Comparing Unicompartmental vs. Total Knee Arthroplasty: Differences in Knee Kinematics},
journal = {Medicina},
year = {2026},
volume = {62},
number = {4},
pages = {648},
doi = {10.3390/medicina62040648}
}
EUVIMED