EUVIMEDEUVIMED entdecken
Crossref

No significant association between quadriceps tendon alignment and 1‐year patient‐reported outcomes following physiological total knee arthroplasty without patellar resurfacing

Manabu Akagawa iD, Roberto Berebichez-Fridman, Loic Villet, Charles Rivière

Knee Surgery, Sports Traumatology, Arthroscopy · 2026-12 · 34 (10) · 3655-3663

DOI: 10.1002/ksa.70310 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, online erschienen am 28.01.2026. Verfasst von Manabu Akagawa und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic Surgery, Akita University Graduate School of Medicine, Akita, Japan. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Patient Reported Outcome Measures, Quadriceps Muscle, Tendons. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 38 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This study aimed to clarify the clinical relevance of quadriceps tendon alignment (QTA), focusing on the quadriceps tendon axial angle (QTAx), in patients undergoing ‘physiological total knee arthroplasty (TKA)’. This concept combines unrestricted kinematic alignment (KA) with a medial pivot implant to alter as little as possible the individual knee anatomy and kinematics. It was hypothesised that QTAx would not significantly influence patient‐reported outcomes.

Methods

A retrospective cohort analysis was performed on 54 knees in 50 patients who underwent physiological TKA performed with a non‐KA‐optimised implant design and without patella resurfacing between September 2022 and April 2024. Patient‐reported outcomes, including the Oxford knee score, forgotten joint score, patient's joint perception, pain visual analogue scale and satisfaction visual analogue scale, were evaluated before surgery and at 1 year postoperatively. QTAx was measured on preoperative computed tomography scans. Patients were categorised into three groups according to their QTAx angle: low (mean +1 SD).

Results

Significant improvements were observed in all patient‐reported outcomes 1 year after surgery. QTAx demonstrated no significant correlation with any outcome. Clinical results did not differ significantly among the three QTAx alignment groups, although the high‐angle group tended to show slightly better outcomes. Two patients (3.7%) underwent secondary patellar resurfacing for persistent anterior knee pain.

Conclusions

This study found that variation in QTA, as assessed by QTAx, was not significantly associated with 1‐year clinical outcomes following physiological TKA performed with a non‐KA‐optimised implant and without patellar resurfacing. Our findings suggest that specific surgical techniques to counteract high QTA may not be necessary within the context of physiological TKA. Level of Evidence Level III.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneePatient Reported Outcome MeasuresQuadriceps MuscleTendonsKnee JointHumansFemaleRetrospective StudiesMaleAgedMiddle AgedPatellaBiomechanical PhenomenaKnee ProsthesisPatient Satisfaction

Stichwörter der Autor:innen

kinematic alignmentmedial pivot designpatient‐reported outcomesquadriceps tendon alignmenttotal knee arthroplasty

Autor:innen und Institutionen

  • Department of Orthopedic Surgery, Akita University Graduate School of Medicine, Akita, Japan.
  • Clinique du Sport Bordeaux Mérignac, 4 rue Georges Negrevergne, Mérignac, France.
  • Bordeaux Arthroplasty Research Institute (BARI), 6 rue Georges Negrevergne, Mérignac, France.

ORCID-Profile: Manabu Akagawa

Zitieren

APA

Akagawa, M., Berebichez-Fridman, R., Villet, L., & Rivière, C. (2026). No significant association between quadriceps tendon alignment and 1‐year patient‐reported outcomes following physiological total knee arthroplasty without patellar resurfacing. Knee Surgery, Sports Traumatology, Arthroscopy, 34(10), 3655-3663. https://doi.org/10.1002/ksa.70310

Vancouver

Akagawa M, Berebichez-Fridman R, Villet L, Rivière C. No significant association between quadriceps tendon alignment and 1‐year patient‐reported outcomes following physiological total knee arthroplasty without patellar resurfacing. Knee Surgery, Sports Traumatology, Arthroscopy. 2026;34(10):3655-3663. doi:10.1002/ksa.70310

BibTeX
@article{Akagawa2026,
  author = {Akagawa, Manabu and Berebichez-Fridman, Roberto and Villet, Loic and Rivière, Charles},
  title = {No significant association between quadriceps tendon alignment and 1‐year patient‐reported outcomes following physiological total knee arthroplasty without patellar resurfacing},
  journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
  year = {2026},
  volume = {34},
  number = {10},
  pages = {3655--3663},
  doi = {10.1002/ksa.70310}
}
Kostenlos starten →