EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

The Modified Harrington Procedure for Metastatic Peri-Acetabular Bone Lesion Using a Novel Highly Porous Titanium Revision Shell with Long Lever Arm Screw

Sven Frieler, Carsten Gebert, Yannik Hanusrichter iD, Periklis Godolias, Martin Wessling

Medicina · 2024

DOI: 10.3390/medicina60071047 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medicina, 2024. Verfasst von Sven Frieler und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Tumour Orthopaedics and Revision Arthroplasty, Orthopaedic Hospital Volmarstein, 58300 Wetter, Germany. Hauptthemen laut MEDLINE: Acetabulum, Titanium, Bone Screws, Bone Neoplasms. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and Objectives: Peri-acetabular metastases often lead to significant pain and functional impairment. Surgical interventions, including the Harrington procedure, aim to address these challenges. This study evaluates a modified Harrington procedure using the MUTARS® PRS® (Pelvic Revision Shell) with an 8 mm fixation screw for severe acetabular defects resulting from metastatic lesions. Materials and Methods: Retrospective analysis of 12 patients treated between January 2020 and December 2023 was conducted. The procedure involved using the novel MUTARS® PRS® with an 8 mm in diameter dome screw (length 70–100 mm). Outcome measures included implant positioning changes, complication rates, functional outcomes, implant longevity, and patient survival. Radiological assessments were performed postoperatively, with follow-ups at 3, 6, 12 months, and annually thereafter.

Results

Average follow-up was 15 ± 11 months, with 67% patient survival at 1 year and 44% at 2 years. Implant survivorship remained 100%. Harris Hip Score improved significantly from 37 ± 22 preoperatively to 75 ± 15 at the last follow-up. No revisions involving implant components were reported. Complications occurred in 5 of 12 patients. Overall, PRS® demonstrates effective osseous ingrowth, high primary stability, immediate full weight-bearing, and low complication rates.

Conclusions

PRS® integrates facilitating osseous ingrowth for preferable long-term outcomes, while efficiently transmitting the weight-bearing load to the intact aspect of the pelvis using a long 8 mm lever screw, enhancing the primary stability of the construct. It proves to be an effective and reproducible technique for managing destructive metastatic lesions of the acetabulum and peri-acetabular region, even in irradiated bone.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AcetabulumTitaniumBone ScrewsBone NeoplasmsHumansMaleFemaleRetrospective StudiesMiddle AgedAgedReoperationAdultTreatment OutcomePorosityArthroplasty, Replacement, Hip

Stichwörter der Autor:innen

Harrington procedureMUTARS® PRS®immediate full weight-bearingmodified Harrington procedureosseous ingrowthperi-acetabular metastases

Substanzen

Titanium

Autor:innen und Institutionen

  • Department of Tumour Orthopaedics and Revision Arthroplasty, Orthopaedic Hospital Volmarstein, 58300 Wetter, Germany.
  • Department of Trauma and Orthopaedic Surgery, BG University Hospital Bergmannsheil, Ruhr University Bochum, 44801 Bochum, Germany.
  • Seattle Science Foundation, Seattle, WA 98122, USA.
  • Department of Orthopedics and Tumor Orthopedics, Muenster University Hospital, 48149 Muenster, Germany.
  • Center for Musculoskeletal Surgery, University Hospital of Essen, 45147 Essen, Germany.
  • Department of Orthopedics and Trauma Surgery, St. Josef Hospital Essen-Werden, 45239 Essen, Germany.

ORCID-Profile: Yannik Hanusrichter

Zitieren

APA

Frieler, S., Gebert, C., Hanusrichter, Y., Godolias, P., & Wessling, M. (2024). The Modified Harrington Procedure for Metastatic Peri-Acetabular Bone Lesion Using a Novel Highly Porous Titanium Revision Shell with Long Lever Arm Screw. Medicina. https://doi.org/10.3390/medicina60071047

Vancouver

Frieler S, Gebert C, Hanusrichter Y, Godolias P, Wessling M. The Modified Harrington Procedure for Metastatic Peri-Acetabular Bone Lesion Using a Novel Highly Porous Titanium Revision Shell with Long Lever Arm Screw. Medicina. 2024. doi:10.3390/medicina60071047

BibTeX
@article{Frieler2024,
  author = {Frieler, Sven and Gebert, Carsten and Hanusrichter, Yannik and Godolias, Periklis and Wessling, Martin},
  title = {The Modified Harrington Procedure for Metastatic Peri-Acetabular Bone Lesion Using a Novel Highly Porous Titanium Revision Shell with Long Lever Arm Screw},
  journal = {Medicina},
  year = {2024},
  doi = {10.3390/medicina60071047}
}
Kostenlos starten →