EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Effects of Spatial Loss Mapping and Two-Phase Interface Treatment on the Thermal Prediction of a Direct-Oil-Cooled Traction Motor: A Combined CFD and Dynamometer Study

Sungjin Yang, Yongwoo Shin, Jongrak Choi

Machines · 16.11.2026 · 14 (11) · 1358

DOI: 10.3390/machines14111358 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Machines, online erschienen am 16.11.2026. Verfasst von Sungjin Yang und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Korea Agency for Infrastructure Technology Advancement.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Direct oil cooling allows traction motors to reach high power densities, but their temperature fields are difficult to predict because the electromagnetic losses are spatially non-uniform and the oil–air flow inside the machine is strongly two-phase. This study couples three-dimensional finite element (FEM) losses with conjugate computational fluid dynamics (CFD) for an 8-pole, 48-slot direct-oil-cooled interior permanent magnet traction motor and evaluates two modelling choices against dynamometer tests. Losses were applied either as a homogeneous loss density (HLD) or as a spatial loss distribution (SLD) mapped from the FEM to the CFD mesh by inverse distance weighting. The oil–air flow was solved with a pseudo-transient volume-of-fluid model using a sharp or a dispersion interface treatment. Nine winding and two housing temperatures were measured under continuous load (205 Nm, 4400 r/min) and, as a supplementary check, instantaneous load (400 Nm, 3000 r/min). Under continuous load, the dispersion–HLD model overpredicted the cold-side winding temperature rise by 36.3%, whereas the sharp–SLD model reduced the errors to 4.7%, 1.4% and 0.8% for the cold-side winding, hot-side winding and housing groups. The interface treatment dominated, and SLD gave a consistent secondary improvement. The imposed losses plus the computed churning and bearing losses matched the measured total loss within 5%.

Förderung

  • Korea Agency for Infrastructure Technology Advancement

Zitieren

APA

Yang, S., Shin, Y., & Choi, J. (2026). Effects of Spatial Loss Mapping and Two-Phase Interface Treatment on the Thermal Prediction of a Direct-Oil-Cooled Traction Motor: A Combined CFD and Dynamometer Study. Machines, 14(11), 1358. https://doi.org/10.3390/machines14111358

Vancouver

Yang S, Shin Y, Choi J. Effects of Spatial Loss Mapping and Two-Phase Interface Treatment on the Thermal Prediction of a Direct-Oil-Cooled Traction Motor: A Combined CFD and Dynamometer Study. Machines. 2026;14(11):1358. doi:10.3390/machines14111358

BibTeX
@article{Yang2026,
  author = {Yang, Sungjin and Shin, Yongwoo and Choi, Jongrak},
  title = {Effects of Spatial Loss Mapping and Two-Phase Interface Treatment on the Thermal Prediction of a Direct-Oil-Cooled Traction Motor: A Combined CFD and Dynamometer Study},
  journal = {Machines},
  year = {2026},
  volume = {14},
  number = {11},
  pages = {1358},
  doi = {10.3390/machines14111358}
}
Kostenlos starten →