EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Cone-Based Hand–Eye Calibration of a Line Laser Sensor on a Three-Axis Drilling Machine Under Fixed Sensor Orientation

Lei Hao, Xinqi Yang, Chao Chen, Fuxin Du

Machines · 06.11.2026 · 14 (11) · 1311

DOI: 10.3390/machines14111311 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Machines, online erschienen am 06.11.2026. Verfasst von Lei Hao und 3 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the Jinan Special Structures Research Institute of the Aviation Industry Corporation of China, Key Research and Development Program of Shandong Province.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

We address hand–eye calibration for a line laser sensor rigidly mounted on a three-axis drilling machine. The sensor maintains a fixed orientation while the machine provides translation along the X, Y, and Z axes. We propose a cone-assisted hand–eye calibration method for this configuration. Incomplete elliptical profiles acquired at different positions are fitted to reconstruct the cone apex. Reconstructed apex coordinates and machine position readings establish an inter-frame apex-coincidence constraint. Centering both sets of coordinates eliminates the unknown hand–eye translation under fixed orientation. Rotation is estimated by a closed-form singular value decomposition, and the known base-frame apex position determines translation. Noiseless simulations showed near-exact recovery of the prescribed transformation. Fifty Monte Carlo realizations were performed at each of five profile-noise levels. As the coordinate-noise standard deviation increased from 0.01 to 0.20mm, mean rotation error increased from 0.0912∘ to 1.8441∘, mean translation error from 0.2506 to 5.0549mm, and mean transformed apex-position RMSE in the machine base frame from 0.1658 to 3.3506mm. A cone half-angle mismatch of 0.5∘ produced approximately 0.9mm translation error. Near-collinear sampling yielded similar apex-coincidence residuals for substantially different rotations, highlighting the importance of sampling geometry. In the physical calibration and validation experiments, the mean Euclidean localization error was 0.9240±0.4809mm (mean ± sample standard deviation), with a maximum of 1.5816mm. The method enables spatial calibration of a line laser measurement system using multidirectional translation without adjusting the sensor orientation.

Förderung

  • the Jinan Special Structures Research Institute of the Aviation Industry Corporation of China
  • Key Research and Development Program of Shandong Province

Zitieren

APA

Hao, L., Yang, X., Chen, C., & Du, F. (2026). Cone-Based Hand–Eye Calibration of a Line Laser Sensor on a Three-Axis Drilling Machine Under Fixed Sensor Orientation. Machines, 14(11), 1311. https://doi.org/10.3390/machines14111311

Vancouver

Hao L, Yang X, Chen C, Du F. Cone-Based Hand–Eye Calibration of a Line Laser Sensor on a Three-Axis Drilling Machine Under Fixed Sensor Orientation. Machines. 2026;14(11):1311. doi:10.3390/machines14111311

BibTeX
@article{Hao2026,
  author = {Hao, Lei and Yang, Xinqi and Chen, Chao and Du, Fuxin},
  title = {Cone-Based Hand–Eye Calibration of a Line Laser Sensor on a Three-Axis Drilling Machine Under Fixed Sensor Orientation},
  journal = {Machines},
  year = {2026},
  volume = {14},
  number = {11},
  pages = {1311},
  doi = {10.3390/machines14111311}
}
Kostenlos starten →