Numerical and Experimental Investigation of Pressure Pulsation in an LDPE Hyper-Compressor’s Interstage Pipeline
Machines · 24.07.2026 · 14 (8) · 840
DOI: 10.3390/machines14080840 ↗Kurz gefasst
Fachartikel in der Zeitschrift Machines, online erschienen am 24.07.2026. Verfasst von Liya Ma und 4 weiteren Autor:innen. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, China Postdoctoral Science Foundation.
Abstract (Originalsprache)
A hyper compressor is one of the most critical pieces of equipment for synthesizing low-density polyethylene (LDPE) with a discharge pressure up to 350 MPa. Such a high discharge pressure creates significant challenges for safety and reliability. In this study, a 3D transient computational fluid dynamics (CFD) model of a hyper-compressor’s interstage pipeline was adopted to examine the characteristics of pressure pulsation inside the interstage pipeline. First, flow channels of multiple poppets in the combined valve were simplified into a single channel while keeping the flow area identical. A single-degree-of-freedom equation was employed to calculate the dynamic motion of the simplified valve. Then, the acceleration, velocity, and lift of the valve were acquired by accumulating pressure-induced forces. Finally, the entire model was solved, and the p–θ diagram inside the working chambers and the pressure pulsation inside the interstage pipeline were acquired. It was found that the isotropic indexes of compression and expansion processes were 29.1 and 3.17 for the first stage of the hyper-compressor, and 36.85 and 3.65 for the second stage, respectively. The indices were significantly higher than those of the common compressor due to the higher compressibility of ethylene at hyper-pressures. The maximal pressure pulsations around the first stage and the second stage were 17.5% and 16.22%, respectively. Strain gauges were adopted to measure the on-site pressure pulsation. The results showed that the proposed CFD model was able to predict the coupling of thermodynamic processes in the working chamber and pressure pulsation in the pipeline. The comparison between the predicted and measured frequency vs. amplitude diagrams showed that the discrepancies at lower harmonics were smaller than those at higher harmonics. The maximum discrepancy of the dominant harmonic amplitudes between the CFD prediction and the strain gauge measurement was within approximately ±13%.
Förderung
- National Natural Science Foundation of China
- China Postdoctoral Science Foundation
Zitieren
APA
Ma, L., Chen, X., Xiong, W., Ma, Z., & Zhao, B. (2026). Numerical and Experimental Investigation of Pressure Pulsation in an LDPE Hyper-Compressor’s Interstage Pipeline. Machines, 14(8), 840. https://doi.org/10.3390/machines14080840
Vancouver
Ma L, Chen X, Xiong W, Ma Z, Zhao B. Numerical and Experimental Investigation of Pressure Pulsation in an LDPE Hyper-Compressor’s Interstage Pipeline. Machines. 2026;14(8):840. doi:10.3390/machines14080840
BibTeX
@article{Ma2026,
author = {Ma, Liya and Chen, Xingyu and Xiong, Wei and Ma, Zenghui and Zhao, Bin},
title = {Numerical and Experimental Investigation of Pressure Pulsation in an LDPE Hyper-Compressor’s Interstage Pipeline},
journal = {Machines},
year = {2026},
volume = {14},
number = {8},
pages = {840},
doi = {10.3390/machines14080840}
}
EUVIMED