Tensile Behavior of Pre-Embedded Titanium-Alloy Joints in Filament-Wound Carbon-Fiber Composite Tubes After Low-Temperature Conditioning

Xiaoyong Liu iD, Zifei Ma, Siyuan Li, Cheng Guo, Haibo Luo, Jun Wu iD

Materials · 27.10.2026 · 19 (21) · 4526

DOI: 10.3390/ma19214526 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Materials, online erschienen am 27.10.2026. Verfasst von Xiaoyong Liu und 5 weiteren Autor:innen. Beteiligte Einrichtung: Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100094, China. Die Arbeit nennt 56 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, CAS Project for Young Scientists in Basic Research, Postdoctoral Fellowship Program of CPSF.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Pre-embedded metal inserts provide a direct load-introduction path for filament-wound composite tubes without cutting the load-carrying fibers. This study evaluates the room-temperature axial tensile response of T700 carbon-fiber/TDE86 epoxy tubes containing grooved, internally threaded TC4 titanium-alloy inserts after one programmed low-temperature conditioning cycle and separately examines a small ambient end-enlarged configuration. Twenty-one destructive test records were analyzed: nine ambient constant-section (“equal-section”) specimens, nine independent equal-section specimens after a 25 → −70 → 25 °C chamber-setpoint cycle followed by 24 h at room temperature, and three ambient end-enlarged specimens. At 1 mm/min, the three cohorts had mean peak loads of 81.39, 81.31, and 88.26 kN and coefficients of variation of 14.04%, 8.70%, and 7.85%, respectively. The −0.07 kN difference between the two independent equal-section cohort means does not establish equivalence or absence of a conditioning effect, and the three-specimen end-enlarged comparison does not isolate a causal geometry effect. Macroscopic failure was dominated by insert pull-out accompanied by visible adhesive/interfacial separation, laminate-layer damage, attached fragments, and local splitting. Because local slip, bond-line deformation, and system compliance were not measured, equilibrium and competing limit states are used only as a qualitative framework. The results concern post-conditioning room-temperature response, not in situ performance at −70 °C.

Schlagwörter

Stichwörter der Autor:innen

axial tensionfilament-wound carbon-fiber composite tubelow-temperature conditioningpre-embedded titanium-alloy jointpull-out failurestratospheric airship

Autor:innen und Institutionen

  • Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100094, China.
  • School of Space Exploration, University of Chinese Academy of Sciences, Beijing 100040, China.

ORCID-Profile: Xiaoyong Liu, Jun Wu

Förderung

  • National Natural Science Foundation of China
  • CAS Project for Young Scientists in Basic Research
  • Postdoctoral Fellowship Program of CPSF
  • China Postdoctoral Science Foundation
  • Science and Disruptive Technology Program of AIRCAS
  • National Key Research and Development Program of China

Zitieren

APA

Liu, X., Ma, Z., Li, S., Guo, C., Luo, H., & Wu, J. (2026). Tensile Behavior of Pre-Embedded Titanium-Alloy Joints in Filament-Wound Carbon-Fiber Composite Tubes After Low-Temperature Conditioning. Materials, 19(21), 4526. https://doi.org/10.3390/ma19214526

Vancouver

Liu X, Ma Z, Li S, Guo C, Luo H, Wu J. Tensile Behavior of Pre-Embedded Titanium-Alloy Joints in Filament-Wound Carbon-Fiber Composite Tubes After Low-Temperature Conditioning. Materials. 2026;19(21):4526. doi:10.3390/ma19214526

BibTeX
@article{Liu2026,
  author = {Liu, Xiaoyong and Ma, Zifei and Li, Siyuan and Guo, Cheng and Luo, Haibo and Wu, Jun},
  title = {Tensile Behavior of Pre-Embedded Titanium-Alloy Joints in Filament-Wound Carbon-Fiber Composite Tubes After Low-Temperature Conditioning},
  journal = {Materials},
  year = {2026},
  volume = {19},
  number = {21},
  pages = {4526},
  doi = {10.3390/ma19214526}
}