EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Effect of Support Spacing on the Region-Specific Dimensional Accuracy of 3D-Printed Dental Models

Berker Alpöz, Burçin Akan, Ender Akan

Materials · 15.08.2026 · 19 (16) · 3463

DOI: 10.3390/ma19163463 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Materials, online erschienen am 15.08.2026. Verfasst von Berker Alpöz und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, Faculty of Dentistry, Izmir Katip Celebi University, 35620 Izmir, Türkiye. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Additive manufacturing is increasingly integrated into digital prosthodontic workflows for the fabrication of dental models; however, printing-related parameters may influence the dimensional accuracy of clinically relevant regions. This in vitro study evaluated the effect of support spacing on the region-specific dimensional accuracy of masked stereolithography (MSLA)-printed dental models. A standardized typodont model representing a three-unit posterior fixed dental prosthesis preparation in the FDI 24–26 region was digitized to obtain a reference STL dataset. Three support spacing configurations were evaluated: 3 mm, 5 mm, and 7 mm (n = 8 per group). All specimens were fabricated using an MSLA printer and a photopolymer model resin at a layer thickness of 50 μm. After post-processing, the printed models were rescanned and compared with the reference dataset using three-dimensional deviation analysis. Root mean square (RMS) deviations were calculated for global, marginal, intaglio, and adjacent regions. Significant differences were observed in the global (p < 0.001), marginal (p = 0.001), and intaglio (p = 0.010) regions, whereas adjacent regions were not significantly affected (p = 0.070). Increasing support spacing was associated with greater dimensional deviations in the global and intaglio regions. Overall, the 3-mm support spacing demonstrated the most consistent dimensional performance across the evaluated regions. These findings indicate that support spacing is an important design parameter influencing the dimensional predictability of MSLA-printed dental models and highlight the value of region-specific accuracy assessment for optimizing support design in digital prosthodontic workflows.

Schlagwörter

Stichwörter der Autor:innen

additive manufacturingdental modelsdigital dentistrydimensional accuracymasked stereolithographyphotopolymer resinroot mean squaresupport spacing

Autor:innen und Institutionen

  • Department of Prosthodontics, Faculty of Dentistry, Izmir Katip Celebi University, 35620 Izmir, Türkiye.
  • Department of Orthodontics, Faculty of Dentistry, Izmir Katip Celebi University, 35620 Izmir, Türkiye.

Zitieren

APA

Alpöz, B., Akan, B., & Akan, E. (2026). Effect of Support Spacing on the Region-Specific Dimensional Accuracy of 3D-Printed Dental Models. Materials, 19(16), 3463. https://doi.org/10.3390/ma19163463

Vancouver

Alpöz B, Akan B, Akan E. Effect of Support Spacing on the Region-Specific Dimensional Accuracy of 3D-Printed Dental Models. Materials. 2026;19(16):3463. doi:10.3390/ma19163463

BibTeX
@article{Alpz2026,
  author = {Alpöz, Berker and Akan, Burçin and Akan, Ender},
  title = {Effect of Support Spacing on the Region-Specific Dimensional Accuracy of 3D-Printed Dental Models},
  journal = {Materials},
  year = {2026},
  volume = {19},
  number = {16},
  pages = {3463},
  doi = {10.3390/ma19163463}
}
Kostenlos starten →