Fachartikel in der Zeitschrift Materials, online erschienen am 14.08.2026. Verfasst von Yifan Li und 2 weiteren Autor:innen. Beteiligte Einrichtung: School of Metallurgy and Ecological Engineering, University of Science and Technology Beijing, Beijing 100083, China. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Water atomization is widely used for producing FeSiCr alloy powder, in which melt delivery conditions strongly influence jet breakup and powder refinement. In this study, a coupled volume of fluid-discrete phase model (VOF-DPM) was established to investigate the effect of delivery tube diameter (3, 4, 5, and 6 mm) on flow characteristics, interfacial instability, and droplet evolution at a constant water pressure of 120 MPa, and the simulation results were validated by industrial trials. As the tube diameter increased from 3 to 6 mm, the melt mass flow rate rose from 0.100 to 0.368 kg/s, the primary breakup position shifted downstream from 94.6 to 236.5 mm, and the peak negative pressure along the centerline decreased from −41.12 to −31.65 kPa. The simulated average particle size increased from 9.176 to 22.791 μm, while the experimentally measured mean particle size increased from 9.0 to 19.6 μm and the fine-powder yield decreased from 43.77% to 22.28%. Although the 3 mm tube produced the finest powder, it showed a higher tendency for clogging and unstable melt delivery. Overall, the 4 mm delivery tube provided the best balance between powder refinement, size uniformity, and production stability.

Schlagwörter

Stichwörter der Autor:innen

FeSiCr alloy powderdelivery tube diameterindustrial validationpowder refinementwater atomization

Autor:innen und Institutionen

  • School of Metallurgy and Ecological Engineering, University of Science and Technology Beijing, Beijing 100083, China.
  • School of Materials and Physics Science, Nanchang University, Nanchang 330031, China.

ORCID-Profile: Yifan Li, Pu Wang

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Li, Y., Wang, P., & Zhang, J. (2026). Effect of Delivery Tube Diameter on Melt Breakup and Powder Refinement During Water Atomization of FeSiCr Alloy Powder. Materials, 19(16), 3455. https://doi.org/10.3390/ma19163455

Vancouver

Li Y, Wang P, Zhang J. Effect of Delivery Tube Diameter on Melt Breakup and Powder Refinement During Water Atomization of FeSiCr Alloy Powder. Materials. 2026;19(16):3455. doi:10.3390/ma19163455

BibTeX
@article{Li2026,
  author = {Li, Yifan and Wang, Pu and Zhang, Jiaquan},
  title = {Effect of Delivery Tube Diameter on Melt Breakup and Powder Refinement During Water Atomization of FeSiCr Alloy Powder},
  journal = {Materials},
  year = {2026},
  volume = {19},
  number = {16},
  pages = {3455},
  doi = {10.3390/ma19163455}
}
Kostenlos starten →