Debonding Behavior of Resin-Cemented Attachment-Housing Denture-Base Complexes Under Cyclic Mechanical Loading
Materials · 26.05.2026 · 19 (11) · 2246
DOI: 10.3390/ma19112246 ↗Kurz gefasst
Fachartikel in der Zeitschrift Materials, online erschienen am 26.05.2026. Verfasst von Evangelos V Skondras und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, School of Dentistry, Faculty of Health Sciences, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Implant-supported overdentures improve denture retention and patient satisfaction, but debonding of attachment housings from the denture base remains a frequent prosthetic complication. This in vitro study evaluated the influence of attachment-housing and denture-base materials on debonding occurrence and maximum tensile force in resin-cemented attachment housing denture-base complexes subjected to cyclic mechanical loading. Thirty standardized specimens were digitally designed and fabricated from three denture-base materials—polymethylmethacrylate (PMMA) (n = 12), polyetheretherketone (PEEK) (n = 12), and cobalt-chromium (Co-Cr) (n = 6)—and combined with either titanium or PEEK attachment housings, which were bonded with a dual-polymerized resin cement. The specimens were subjected to 1100 cycles of alternating tensile and compressive loading, and debonding occurrence and maximum tensile force were recorded. Debonding occurred in 60% of the specimens and differed significantly among denture base materials. No debond-ing was observed in the Co-Cr specimens, whereas debonding occurred in 75% of the PMMA and PEEK specimens. The Co-Cr specimens also demonstrated significantly higher maximum tensile force values than the PMMA and PEEK groups, while regarding the attachment-housing material, no significant main effect was detected. Within the limitations of this in vitro study, the denture-base material, fabrication, and surface treatment combinations significantly influenced debonding and tensile force during cyclic loading, whereas the attachment-housing material did not demonstrate a significant main effect.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Prosthodontics, School of Dentistry, Faculty of Health Sciences, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece.
- Department of Prosthodontics, Tufts University School of Dental Medicine, Boston, MA 02111, USA.
- Skondras Dental Center, 14671 Kifissia, Greece.
- Impact-BZ, London SW11 5QL, UK.
- Department of Geology, Schools of Sciences, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece.
ORCID-Profile: Savvas N Kamalakidis, Antonios Bouzakis, Lambrini Papadopoulou, Eleana Kontonasaki, Olga Naka
Zitieren
APA
Skondras, E. V., Kamalakidis, S. N., Skondra, E., Bouzakis, A., Papadopoulou, L., Kontonasaki, E., & Naka, O. (2026). Debonding Behavior of Resin-Cemented Attachment-Housing Denture-Base Complexes Under Cyclic Mechanical Loading. Materials, 19(11), 2246. https://doi.org/10.3390/ma19112246
Vancouver
Skondras EV, Kamalakidis SN, Skondra E, Bouzakis A, Papadopoulou L, Kontonasaki E, et al. Debonding Behavior of Resin-Cemented Attachment-Housing Denture-Base Complexes Under Cyclic Mechanical Loading. Materials. 2026;19(11):2246. doi:10.3390/ma19112246
BibTeX
@article{Skondras2026,
author = {Skondras, Evangelos V and Kamalakidis, Savvas N and Skondra, Eftychia and Bouzakis, Antonios and Papadopoulou, Lambrini and Kontonasaki, Eleana and Naka, Olga},
title = {Debonding Behavior of Resin-Cemented Attachment-Housing Denture-Base Complexes Under Cyclic Mechanical Loading},
journal = {Materials},
year = {2026},
volume = {19},
number = {11},
pages = {2246},
doi = {10.3390/ma19112246}
}
EUVIMED