EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Optimization and Comparative Study of Non-Pressurized Shell-and-Tube Latent Heat Storage for Air-Source Heat Pump Systems: Numerical and Experimental Investigation

Weilin Li, Yuguo Fu, Hanrui Wang, Xingtao Zhang

Materials · 12.05.2026 · 19 (10) · 2014

DOI: 10.3390/ma19102014 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Materials, online erschienen am 12.05.2026. Verfasst von Weilin Li und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Civil Engineering, Zhengzhou University, Zhengzhou 450001, China. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To mitigate the spatiotemporal mismatch between renewable energy supply and building heating demand, this study proposes a novel non-pressurized shell-and-tube latent heat storage (NP-LHS) device coupled with an air-source heat pump (ASHP) system. To overcome the inherent low thermal conductivity of organic phase change materials (PCMs), the thermal performances of plain, corrugated, and finned tubes were systematically compared using both computational fluid dynamics (CFD) simulations and full-scale experiments. Numerical results indicate that the optimal tube spacing ratio ranges from 1.0 to 1.5. Among the evaluated geometries, the finned tube configuration exhibited superior comprehensive performance. It achieved an exceptionally high PCM volume fraction of 92.5% and dramatically reduced the complete melting time to 180 min—significantly faster than both corrugated (280 min) and bare tubes—while attaining a higher terminal temperature. Full-cycle dynamic experiments further demonstrated that integrating the finned tube NP-LHS into the ASHP system yielded a peak-shaving power reduction rate of 98.0%, effectively maintaining indoor thermal comfort. These findings conclude that expanding the conductive surface area via fins is practically more effective than inducing fluid turbulence for low-conductivity PCMs in non-pressurized storage applications.

Schlagwörter

Stichwörter der Autor:innen

air-source heat pump systemcorrugated tube enhanced heat transferfinned tube enhanced heat transferlatent heat storageshell-and-tube heat exchanger

Autor:innen und Institutionen

  • School of Civil Engineering, Zhengzhou University, Zhengzhou 450001, China.

Zitieren

APA

Li, W., Fu, Y., Wang, H., & Zhang, X. (2026). Optimization and Comparative Study of Non-Pressurized Shell-and-Tube Latent Heat Storage for Air-Source Heat Pump Systems: Numerical and Experimental Investigation. Materials, 19(10), 2014. https://doi.org/10.3390/ma19102014

Vancouver

Li W, Fu Y, Wang H, Zhang X. Optimization and Comparative Study of Non-Pressurized Shell-and-Tube Latent Heat Storage for Air-Source Heat Pump Systems: Numerical and Experimental Investigation. Materials. 2026;19(10):2014. doi:10.3390/ma19102014

BibTeX
@article{Li2026,
  author = {Li, Weilin and Fu, Yuguo and Wang, Hanrui and Zhang, Xingtao},
  title = {Optimization and Comparative Study of Non-Pressurized Shell-and-Tube Latent Heat Storage for Air-Source Heat Pump Systems: Numerical and Experimental Investigation},
  journal = {Materials},
  year = {2026},
  volume = {19},
  number = {10},
  pages = {2014},
  doi = {10.3390/ma19102014}
}
Kostenlos starten →