EUVIMEDObjevte EUVIMED
Open access · CC BY 4.0

Influence of Immediate Versus Delayed Loading on Peri-Implant Bone Healing: A Comparative FEA Study of Titanium Threaded and Scaffold Dental Implants

Giuseppe Casalino iD, Mario Ceddia iD, Nicola Contuzzi iD, Luciano Lamberti, Bartolomeo Trentadue iD

Materials · 2026-04-16 · 19 (8) · 1607

DOI: 10.3390/ma19081607 ↗

At a glance

Journal article in Materials, published online on 2026-04-16. Written by Giuseppe Casalino and 4 co-authors. Institution: Department of Mechanics, Mathematics and Management, Polytechnic University of Bari, 70125 Bari, Italy. Cited 1 times so far (Crossref); 75 references. The full text is freely available (open access, CC BY 4.0).

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Background

Immediate loading of dental implants shortens treatment time and improves early function, but it also exposes the healing peri-implant tissue to a critical mechanical environment. This study compared the biomechanical and mechanobiological response of a conventional threaded implant and a porous scaffold-based implant under immediate and delayed loading conditions.

Methods

A three-dimensional finite element model of a bone block with a 0.2 mm peri-implant callus was developed in ABAQUS/Standard. Model A was a threaded Ti-6Al-4V implant, while Model B was a porous implant with 64.26% porosity. Bone tissues were modeled as poroelastic materials. Immediate and delayed loading were simulated through frictional and tied bone-implant interfaces, respectively. Mechanobiological predictions were performed using the Prendergast-Huiskes stimulus.

Results

Under immediate loading, the porous implant reduced cortical bone stress (32.5 MPa vs. 88 MPa) and markedly increased callus stimulation (20.5–31.6 MPa vs. about 2.5 MPa) compared with the threaded implant. Mechanobiological analysis showed that Model B promoted higher fractions of immature and mature bone and lower fractions of cartilage and fibrous tissue. In all cases, implant stresses remained below the yield strength of the corresponding materials.

Conclusions

The porous implant provided a more favorable mechanical environment for early peri-implant healing, particularly under immediate loading, and may be a promising strategy to enhance callus maturation and reduce stress shielding.

Subjects

Author keywords

dental implantfinite element analysisporous implantstress shielding

Authors and institutions

  • Department of Mechanics, Mathematics and Management, Polytechnic University of Bari, 70125 Bari, Italy.

ORCID profiles: Giuseppe Casalino, Mario Ceddia, Nicola Contuzzi, Bartolomeo Trentadue

Cite

APA

Casalino, G., Ceddia, M., Contuzzi, N., Lamberti, L., & Trentadue, B. (2026). Influence of Immediate Versus Delayed Loading on Peri-Implant Bone Healing: A Comparative FEA Study of Titanium Threaded and Scaffold Dental Implants. Materials, 19(8), 1607. https://doi.org/10.3390/ma19081607

Vancouver

Casalino G, Ceddia M, Contuzzi N, Lamberti L, Trentadue B. Influence of Immediate Versus Delayed Loading on Peri-Implant Bone Healing: A Comparative FEA Study of Titanium Threaded and Scaffold Dental Implants. Materials. 2026;19(8):1607. doi:10.3390/ma19081607

BibTeX
@article{Casalino2026,
  author = {Casalino, Giuseppe and Ceddia, Mario and Contuzzi, Nicola and Lamberti, Luciano and Trentadue, Bartolomeo},
  title = {Influence of Immediate Versus Delayed Loading on Peri-Implant Bone Healing: A Comparative FEA Study of Titanium Threaded and Scaffold Dental Implants},
  journal = {Materials},
  year = {2026},
  volume = {19},
  number = {8},
  pages = {1607},
  doi = {10.3390/ma19081607}
}
Start for free →