EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Influence of Immediate Versus Delayed Loading on Peri-Implant Bone Healing: A Comparative FEA Study of Titanium Threaded and Scaffold Dental Implants

Giuseppe Casalino iD, Mario Ceddia iD, Nicola Contuzzi iD, Luciano Lamberti, Bartolomeo Trentadue iD

Materials · 16.04.2026 · 19 (8) · 1607

DOI: 10.3390/ma19081607 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Materials, online erschienen am 16.04.2026. Verfasst von Giuseppe Casalino und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanics, Mathematics and Management, Polytechnic University of Bari, 70125 Bari, Italy. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 75 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Immediate loading of dental implants shortens treatment time and improves early function, but it also exposes the healing peri-implant tissue to a critical mechanical environment. This study compared the biomechanical and mechanobiological response of a conventional threaded implant and a porous scaffold-based implant under immediate and delayed loading conditions.

Methods

A three-dimensional finite element model of a bone block with a 0.2 mm peri-implant callus was developed in ABAQUS/Standard. Model A was a threaded Ti-6Al-4V implant, while Model B was a porous implant with 64.26% porosity. Bone tissues were modeled as poroelastic materials. Immediate and delayed loading were simulated through frictional and tied bone-implant interfaces, respectively. Mechanobiological predictions were performed using the Prendergast-Huiskes stimulus.

Results

Under immediate loading, the porous implant reduced cortical bone stress (32.5 MPa vs. 88 MPa) and markedly increased callus stimulation (20.5–31.6 MPa vs. about 2.5 MPa) compared with the threaded implant. Mechanobiological analysis showed that Model B promoted higher fractions of immature and mature bone and lower fractions of cartilage and fibrous tissue. In all cases, implant stresses remained below the yield strength of the corresponding materials.

Conclusions

The porous implant provided a more favorable mechanical environment for early peri-implant healing, particularly under immediate loading, and may be a promising strategy to enhance callus maturation and reduce stress shielding.

Schlagwörter

Stichwörter der Autor:innen

dental implantfinite element analysisporous implantstress shielding

Autor:innen und Institutionen

  • Department of Mechanics, Mathematics and Management, Polytechnic University of Bari, 70125 Bari, Italy.

ORCID-Profile: Giuseppe Casalino, Mario Ceddia, Nicola Contuzzi, Bartolomeo Trentadue

Zitieren

APA

Casalino, G., Ceddia, M., Contuzzi, N., Lamberti, L., & Trentadue, B. (2026). Influence of Immediate Versus Delayed Loading on Peri-Implant Bone Healing: A Comparative FEA Study of Titanium Threaded and Scaffold Dental Implants. Materials, 19(8), 1607. https://doi.org/10.3390/ma19081607

Vancouver

Casalino G, Ceddia M, Contuzzi N, Lamberti L, Trentadue B. Influence of Immediate Versus Delayed Loading on Peri-Implant Bone Healing: A Comparative FEA Study of Titanium Threaded and Scaffold Dental Implants. Materials. 2026;19(8):1607. doi:10.3390/ma19081607

BibTeX
@article{Casalino2026,
  author = {Casalino, Giuseppe and Ceddia, Mario and Contuzzi, Nicola and Lamberti, Luciano and Trentadue, Bartolomeo},
  title = {Influence of Immediate Versus Delayed Loading on Peri-Implant Bone Healing: A Comparative FEA Study of Titanium Threaded and Scaffold Dental Implants},
  journal = {Materials},
  year = {2026},
  volume = {19},
  number = {8},
  pages = {1607},
  doi = {10.3390/ma19081607}
}
Kostenlos starten →