EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Dimensional Accuracy of Regular- and Fast-Setting Vinyl Polysiloxane Impressions Using Customized Metal and Plastic Trays—An In Vitro Study

Moritz Waldecker iD, Karla Jetter, Stefan Rues iD, Peter Rammelsberg, Andreas Zenthöfer

Materials · 07.05.2025 · 18 (9) · 2164

DOI: 10.3390/ma18092164 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Materials, online erschienen am 07.05.2025. Verfasst von Moritz Waldecker und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthetic Dentistry, University Hospital Heidelberg, University of Heidelberg, 69120 Heidelberg, Germany. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The aim of this study was to compare the dimensional accuracy of vinyl polysiloxane impressions differing in terms of curing time (regular-setting (RS) or fast-setting (FS)) in combination with different tray materials (metal (M) and plastic (P)). A typodont reference model simulated a partially edentulous maxilla. Reference points were given by center points of either precision balls welded to specific teeth or finishing-line centers of prepared teeth. These reference points enabled the detection of dimensional deviations between the digitized reference and the scans of the models achieved from the study impressions. Twenty impressions were made for each of the following four test groups: RS-M, RS-P, FS-M and FS-P. Global scan data accuracy was measured by distance and tooth axis deviations from the reference, while local accuracy was determined based on the trueness and precision of the abutment tooth surfaces. Statistical analysis was conducted using ANOVA accompanied by pairwise Tukey post hoc tests (α = 0.05). Most of the distances tended to be underestimated. Global accuracy was favorable; even for long distances, the mean absolute distance deviations were < 100 µm. Local accuracy was excellent for all test groups, with trueness ≤ 11 µm and precision ≤ 9 µm. Within the limitations of this study, all impression and tray materials were suitable to fabricate models with clinically acceptable accuracy.

Schlagwörter

Stichwörter der Autor:innen

accuracyfast-settingimpressionregular-settingtray materialvinyl polysiloxane

Autor:innen und Institutionen

  • Department of Prosthetic Dentistry, University Hospital Heidelberg, University of Heidelberg, 69120 Heidelberg, Germany.

ORCID-Profile: Moritz Waldecker, Stefan Rues

Zitieren

APA

Waldecker, M., Jetter, K., Rues, S., Rammelsberg, P., & Zenthöfer, A. (2025). Dimensional Accuracy of Regular- and Fast-Setting Vinyl Polysiloxane Impressions Using Customized Metal and Plastic Trays—An In Vitro Study. Materials, 18(9), 2164. https://doi.org/10.3390/ma18092164

Vancouver

Waldecker M, Jetter K, Rues S, Rammelsberg P, Zenthöfer A. Dimensional Accuracy of Regular- and Fast-Setting Vinyl Polysiloxane Impressions Using Customized Metal and Plastic Trays—An In Vitro Study. Materials. 2025;18(9):2164. doi:10.3390/ma18092164

BibTeX
@article{Waldecker2025,
  author = {Waldecker, Moritz and Jetter, Karla and Rues, Stefan and Rammelsberg, Peter and Zenthöfer, Andreas},
  title = {Dimensional Accuracy of Regular- and Fast-Setting Vinyl Polysiloxane Impressions Using Customized Metal and Plastic Trays—An In Vitro Study},
  journal = {Materials},
  year = {2025},
  volume = {18},
  number = {9},
  pages = {2164},
  doi = {10.3390/ma18092164}
}
Kostenlos starten →