Dental Implant with Porous Structure and Anchorage: Design and Bench Testing in a Calf Rib Model Study
Materials · 05.02.2025 · 18 (3) · 700
DOI: 10.3390/ma18030700 ↗Kurz gefasst
Fachartikel in der Zeitschrift Materials, online erschienen am 05.02.2025. Verfasst von Keila Lovera und 6 weiteren Autor:innen. Beteiligte Einrichtung: CDL Clínica Dental Lovera, Avenida Cornellà, 2-BJ, Esplugues de Llobregat, 08950 Barcelona, Spain. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 76 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Clínica Dental Lovera, Avenida Cornellà.
Abstract (Originalsprache)
Primary dental implant stability is critical to enable osseointegration. We assessed the primary stability of our newly designed dental implant. We used the calf rib bone animal model. Our implant has an outside tapered screw with two inside barrettes that deploy with a second screw situated at the implant’s crown. We used ten calf ribs with III/IV bone density and inserted ten implants per rib. We deployed the barrettes in the calf rib’s transversal direction to support against the nearby cortical bone. We measured the primary implant’s stability with resonance frequency analysis and collected the Implant Stability Quota (ISQ) in the transverse and longitudinal calf rib planes before (PRE) and after (POS) deploying the barrette. The mean ISQ was PRE 84.00 ± 3.56 and POS 84.73 ± 4.53 (p = 0.84) in the longitudinal plane and PRE 81.80 ± 2.74 and POS 83.53 ± 4.53 (0.27) in the transverse plane. The barrettes’ insertion increases our dental implant primary stability by 11% in the transverse plane and 2% in the longitudinal plane. Our dental implant ISQ values are in the higher range than those reported in the literature and reflect high primary stability after insertion. The barrette deployment improves the dental implant’s primary stability, particularly in the direction in which it deploys (transverse plane).
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- CDL Clínica Dental Lovera, Avenida Cornellà, 2-BJ, Esplugues de Llobregat, 08950 Barcelona, Spain.
- Faculty of Medicine and Odontology, Department of Surgery, University of Valencia, 46010 Valencia, Spain.
- Biomechanics Institute of Valencia, Polytechnic University of Valencia, 46022 Valencia, Spain.
- Hospital General Universitario de Castellón, 12004 Castellón de la Plana, Spain.
- Hospital General Universitario de Valencia, 46014 Valencia, Spain.
- Medius Klinik, Ostfildern-Ruit Klinik für Urologie, Hedelfinger Strasse 166, 73760 Ostfildern, Germany.
ORCID-Profile: Vicente Vanaclocha, Pablo Jordá-Gómez, Nieves Saiz-Sapena
Förderung
- Clínica Dental Lovera, Avenida Cornellà
Zitieren
APA
Lovera, K., Vanaclocha, V., Atienza, C. M., Vanaclocha, A., Jordá-Gómez, P., Saiz-Sapena, N., & Vanaclocha, L. (2025). Dental Implant with Porous Structure and Anchorage: Design and Bench Testing in a Calf Rib Model Study. Materials, 18(3), 700. https://doi.org/10.3390/ma18030700
Vancouver
Lovera K, Vanaclocha V, Atienza CM, Vanaclocha A, Jordá-Gómez P, Saiz-Sapena N, et al. Dental Implant with Porous Structure and Anchorage: Design and Bench Testing in a Calf Rib Model Study. Materials. 2025;18(3):700. doi:10.3390/ma18030700
BibTeX
@article{Lovera2025,
author = {Lovera, Keila and Vanaclocha, Vicente and Atienza, Carlos M and Vanaclocha, Amparo and Jordá-Gómez, Pablo and Saiz-Sapena, Nieves and Vanaclocha, Leyre},
title = {Dental Implant with Porous Structure and Anchorage: Design and Bench Testing in a Calf Rib Model Study},
journal = {Materials},
year = {2025},
volume = {18},
number = {3},
pages = {700},
doi = {10.3390/ma18030700}
}