Coating Materials to Prevent Screw Loosening in Single Dental Implant Crowns: A Systematic Review
Materials · 16.10.2024 · 17 (20) · 5053
DOI: 10.3390/ma17205053 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Materials, online erschienen am 16.10.2024. Verfasst von Lara Coelho und 6 weiteren Autor:innen. Beteiligte Einrichtung: UNIPRO-Oral Pathology and Rehabilitation Research Unit, University Institute of Health Sciences (IUCS), CESPU, 4585-116 Gandra, Portugal. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Oral rehabilitation with dental implants has resulted in high success rates. However, some complications have been described, such as the loss of the prosthetic screw. Some manufacturers sell screws with different coatings to avoid screw loosening, but even these types of screws can come loose. We aimed to investigate the screw coatings that can be applied during a dental appointment to avoid screw loosening. Following PRISMA Guidelines, we searched PubMed/Medline, Embase and Web of Science for studies published up to January 2024. All studies of single dental implant crowns, in which the prosthetic screw was coated with a lubricant and the preload and/or the removal torque value (RTV) was recorded, were analyzed. We excluded studies applying the finite element method (FEM) as well as studies without a control group. The risk of bias was assessed with a tool developed by our research group. Of the 1959 records identified, 19 were selected. Ten studies were considered to have a low risk of bias, and nine were considered to have a medium risk of bias. The coatings tested were adhesives, saliva, chlorhexidine, Vaseline, silicone gel, Polytetrafluoroethylene (PTFE) tape, blood, fluoride, Listerine® Mouthwash and normal saline. The preload, the RTV with and without cyclic loading and the percentage of RTV loss were recorded. Some coatings show promise, although there is no clear evidence that any option is superior in minimizing screw loosening.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- UNIPRO-Oral Pathology and Rehabilitation Research Unit, University Institute of Health Sciences (IUCS), CESPU, 4585-116 Gandra, Portugal.
- Human Anatomy and Embryology Unit, Faculty of Medicine and Health Sciences, University of Barcelona, 08007 Barcelona, Spain.
ORCID-Profile: Lara Coelho, Maria-Cristina Manzanares-Céspedes, Joana Mendes, Carlos Aroso, José Manuel Mendes
Zitieren
APA
Coelho, L., Manzanares-Céspedes, M. C., Mendes, J., Tallón-Walton, V., Astudillo-Rozas, W., Aroso, C., & Mendes, J. M. (2024). Coating Materials to Prevent Screw Loosening in Single Dental Implant Crowns: A Systematic Review. Materials, 17(20), 5053. https://doi.org/10.3390/ma17205053
Vancouver
Coelho L, Manzanares-Céspedes MC, Mendes J, Tallón-Walton V, Astudillo-Rozas W, Aroso C, et al. Coating Materials to Prevent Screw Loosening in Single Dental Implant Crowns: A Systematic Review. Materials. 2024;17(20):5053. doi:10.3390/ma17205053
BibTeX
@article{Coelho2024,