EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Comparative Analysis of NiTi Instruments with Different Alloy Treatments

José Aranguren iD, Felipe Oliveros-Porras, Ana Ramírez-Muñoz, Irene Pérez, Marcela Salamanca-Ramos, Karim Aazzouzi-Raiss, Alejandro R Pérez

Materials · 30.09.2024 · 17 (19) · 4817

DOI: 10.3390/ma17194817 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Materials, online erschienen am 30.09.2024. Verfasst von José Aranguren und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Endodontics, Rey Juan Carlos University, 28933 Madrid, Spain. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study aims to compare the cyclic fatigue resistance of nickel–titanium (NiTi) endodontic instruments, focusing on the impact of various alloy treatments and manufacturing processes across different generations of these instruments; Twenty instrumentation systems from different generations, comprising both continuous and reciprocating motion designs, were tested. Four hundred instruments underwent cyclic fatigue testing using an INSTRON machine, with the time and number of cycles to fracture (NCF) recorded for each instrument. Statistical analyses were performed to compare the fatigue resistance between systems, generations, and motion types; Instruments treated with advanced thermal processing, such as Excalibur, Reciproc Blue, and TruNatomy, demonstrated superior resistance to fracture, whereas systems like Protaper Universal, K3XF, and 2Shape showed the lowest resistance. Reciprocating instruments generally exhibited higher cyclic fatigue resistance than continuously rotating instruments; Technological advancements in NiTi instrument design, especially the implementation of heat-treated alloys, have improved cyclic fatigue resistance, enhancing the safety and efficiency of endodontic treatments. Reciprocating systems, in particular, exhibit superior fracture resistance, suggesting their greater utility in challenging clinical conditions.

Schlagwörter

Stichwörter der Autor:innen

cyclic fatigue resistanceendodontic file systemsnickel–titanium instrumentsroot canal instrumentation

Autor:innen und Institutionen

  • Department of Endodontics, Rey Juan Carlos University, 28933 Madrid, Spain.

ORCID-Profile: José Aranguren

Zitieren

APA

Aranguren, J., Oliveros-Porras, F., Ramírez-Muñoz, A., Pérez, I., Salamanca-Ramos, M., Aazzouzi-Raiss, K., & Pérez, A. R. (2024). Comparative Analysis of NiTi Instruments with Different Alloy Treatments. Materials, 17(19), 4817. https://doi.org/10.3390/ma17194817

Vancouver

Aranguren J, Oliveros-Porras F, Ramírez-Muñoz A, Pérez I, Salamanca-Ramos M, Aazzouzi-Raiss K, et al. Comparative Analysis of NiTi Instruments with Different Alloy Treatments. Materials. 2024;17(19):4817. doi:10.3390/ma17194817

BibTeX
@article{Aranguren2024,
  author = {Aranguren, José and Oliveros-Porras, Felipe and Ramírez-Muñoz, Ana and Pérez, Irene and Salamanca-Ramos, Marcela and Aazzouzi-Raiss, Karim and Pérez, Alejandro R},
  title = {Comparative Analysis of NiTi Instruments with Different Alloy Treatments},
  journal = {Materials},
  year = {2024},
  volume = {17},
  number = {19},
  pages = {4817},
  doi = {10.3390/ma17194817}
}
Kostenlos starten →