Determination of Fluorine by Ion-Selective Electrode and High-Resolution Continuum Source Graphite Furnace Molecular Absorption Spectrometry with Respect to Animal Feed Safety
Materials · 09.06.2024 · 17 (12) · 2812
DOI: 10.3390/ma17122812 ↗Kurz gefasst
Fachartikel in der Zeitschrift Materials, online erschienen am 09.06.2024. Verfasst von Zofia Kowalewska und 4 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Civil Engineering, Mechanics and Petrochemistry, Warsaw University of Technology, Łukasiewicza 17, 09-410 Plock, Poland. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Warsaw University of Technology, Warsaw University of Technology within the Excellence Initiative: Research University (IDUB) program.
Abstract (Originalsprache)
Fluorine, depending on its concentration and chemical form, is essential or toxic to humans and animals. Therefore, it is crucial to be able to determine it reliably. In this study, fluorine was determined in animal feed after extraction with HCl (gastric juice simulation). The standard potentiometric method with a fluoride-selective electrode (ISE) and newly developed high-resolution continuum source graphite furnace molecular absorption spectrometry (HR-CS GFMAS) method was applied. Feed samples turned out to be a challenge for HR-CS GFMAS. Chemical interferences (formation of competing molecules, CaF, GaCl, and GaP, instead of the target GaF molecule) and spectral effects (including a phosphorous molecule spectrum and atomic lines) were identified. An additional difficulty was caused by reagent contamination with F and memory effects. Difficulties were eliminated/reduced. The quality of ISE analysis was multi-directionally verified (including comprehensive proficiency testing). A risk of inaccuracy at low F concentration, where the calibration relationship is nonlinear, was investigated. The results of both methods were consistent, which confirms the accuracy of the methods and informs that the extracted fluorine is in fluoride form. The results of extensive ISE tests conducted in Poland in 2021–2023 have shown that, in most cases, the fluoride content is significantly lower than the threshold values.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Faculty of Civil Engineering, Mechanics and Petrochemistry, Warsaw University of Technology, Łukasiewicza 17, 09-410 Plock, Poland.
- National Laboratory for Feedingstuffs, National Research Institute of Animal Production, Chmielna 2 Str., 20-079 Lublin, Poland.
- Department of Pharmacology, Toxicology and Environmental Protection, Faculty of Veterinary Medicine, University of Life Sciences, Akademicka Sq. 12, 20-950 Lublin, Poland.
- Department of Analytical Chemistry, Institute of Chemical Sciences, Faculty of Chemistry, Maria Curie-Sklodowska University, M. C. Sklodowska Sq. 3, 20-031 Lublin, Poland.
ORCID-Profile: Zofia Kowalewska, Waldemar Korol, Ryszard Dobrowolski
Förderung
- Warsaw University of Technology
- Warsaw University of Technology within the Excellence Initiative: Research University (IDUB) program
Zitieren
APA
Kowalewska, Z., Goluch, K., Korol, W., Olchowski, R., & Dobrowolski, R. (2024). Determination of Fluorine by Ion-Selective Electrode and High-Resolution Continuum Source Graphite Furnace Molecular Absorption Spectrometry with Respect to Animal Feed Safety. Materials, 17(12), 2812. https://doi.org/10.3390/ma17122812
Vancouver
Kowalewska Z, Goluch K, Korol W, Olchowski R, Dobrowolski R. Determination of Fluorine by Ion-Selective Electrode and High-Resolution Continuum Source Graphite Furnace Molecular Absorption Spectrometry with Respect to Animal Feed Safety. Materials. 2024;17(12):2812. doi:10.3390/ma17122812
BibTeX
@article{Kowalewska2024,
author = {Kowalewska, Zofia and Goluch, Karolina and Korol, Waldemar and Olchowski, Rafał and Dobrowolski, Ryszard},
title = {Determination of Fluorine by Ion-Selective Electrode and High-Resolution Continuum Source Graphite Furnace Molecular Absorption Spectrometry with Respect to Animal Feed Safety},
journal = {Materials},
year = {2024},
volume = {17},
number = {12},
pages = {2812},
doi = {10.3390/ma17122812}
}
EUVIMED