EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Cyclic Fatigue of Different Reciprocating Endodontic Instruments Using Matching Artificial Root Canals at Body Temperature In Vitro

Sebastian Bürklein iD, Paul Maßmann iD, Edgar Schäfer iD, David Donnermeyer iD

Materials · 08.02.2024 · 17 (4) · 827

DOI: 10.3390/ma17040827 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Materials, online erschienen am 08.02.2024. Verfasst von Sebastian Bürklein und 3 weiteren Autor:innen. Beteiligte Einrichtung: Central Interdisciplinary Ambulance in the School of Dentistry, University of Münster, 48149 Münster, Germany. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Reciprocating motion expands the lifetime of endodontic instruments during the preparation of severely curved root canals. This study aimed to investigate the time to fracture (TTF) and number of cycles to failure (NCF) of different reciprocating instruments (n = 20 in each group) at body temperature using a dynamic testing model (amplitude = 3 mm). Reciproc Blue (RPB), size 25/.08, WaveOne Gold (WOG) 25/.07, Procodile (Proc) 25/.06, R-Motion (RM_06) 25/.06 and R-Motion (RM_04) 30/.04 instruments were tested in their specific reciprocating motion in artificial matching root canals (size of the instrument ± 0.02 mm; angle of curvature 60°, radius 5.0 mm, and centre of curvature 5.0 mm from apical endpoint). The number of fractured instruments, TTF, NCF, the and lengths of the fractured instruments were recorded and statistically analysed using the Chi-Square or Kruskal–Wallis test. Both TTF (median 720, 643, 562, 406, 254 s) and the NCF (3600, 3215, 2810, 2032, 1482 cycles) decreased in the following order RM_06 > RPB > RM_04 > Proc > WOG with partially significant differences. During testing, only six RM_06 instruments fractured, whereas 16/20 (RPB), 18/20 (Proc), and 20/20 (RM_04, WOG) fractures were recorded (p < 0.05). Within the limitations of the present study, blue-coloured RPB and RM instruments exhibited a significantly superior cyclic fatigue resistance compared to SE-NiTi and Gold-wire instruments. Heat treatment, cross-sectional design and core mass significantly influenced the longevity of reciprocating instruments in cyclic dynamic testing.

Schlagwörter

Stichwörter der Autor:innen

NiTiamplitudecycles to failuredynamic testinglifetimereciprocating motion

Autor:innen und Institutionen

  • Central Interdisciplinary Ambulance in the School of Dentistry, University of Münster, 48149 Münster, Germany.
  • Department of Periodontology and Operative Dentistry, University of Münster, 48149 Münster, Germany.

ORCID-Profile: Sebastian Bürklein, Paul Maßmann, Edgar Schäfer, David Donnermeyer

Zitieren

APA

Bürklein, S., Maßmann, P., Schäfer, E., & Donnermeyer, D. (2024). Cyclic Fatigue of Different Reciprocating Endodontic Instruments Using Matching Artificial Root Canals at Body Temperature In Vitro. Materials, 17(4), 827. https://doi.org/10.3390/ma17040827

Vancouver

Bürklein S, Maßmann P, Schäfer E, Donnermeyer D. Cyclic Fatigue of Different Reciprocating Endodontic Instruments Using Matching Artificial Root Canals at Body Temperature In Vitro. Materials. 2024;17(4):827. doi:10.3390/ma17040827

BibTeX
@article{Brklein2024,
  author = {Bürklein, Sebastian and Maßmann, Paul and Schäfer, Edgar and Donnermeyer, David},
  title = {Cyclic Fatigue of Different Reciprocating Endodontic Instruments Using Matching Artificial Root Canals at Body Temperature In Vitro},
  journal = {Materials},
  year = {2024},
  volume = {17},
  number = {4},
  pages = {827},
  doi = {10.3390/ma17040827}
}
Kostenlos starten →