EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Flow Front Monitoring in High-Pressure Resin Transfer Molding Using Phased Array Ultrasonic Testing to Optimize Mold Filling Simulations

Linus Littner, Richard Protz, Eckart Kunze iD, Yannick Bernhardt, Marc Kreutzbruck, Maik Gude iD

Materials · 30.12.2023 · 17 (1) · 207

DOI: 10.3390/ma17010207 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Materials, online erschienen am 30.12.2023. Verfasst von Linus Littner und 5 weiteren Autor:innen. Beteiligte Einrichtung: Institut für Kunststofftechnik (IKT), University of Stuttgart, 70569 Stuttgart, Germany. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deutsche Forschungsgemeinschaft, Deutsche Forschungsgemeinschaft e.V. (DFG).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

During the production of fiber-reinforced plastics using resin transfer molding (RTM), various characteristic defects and flaws can occur, such as fiber displacement and fiber waviness. Particularly in high-pressure RTM (HP-RTM), fiber misalignments are generated during infiltration by local peaks in the flow rate, leading to a significant reduction in the mechanical properties. To minimize or avoid this effect, the manufacturing process must be well controlled. Simulative approaches allow for a basic design of the mold filling process; however, due to the high number of influencing variables, the real behavior cannot be exactly reproduced. The focus of this work is on flow front monitoring in an HP-RTM mold using phased array ultrasonic testing. By using an established non-destructive testing instrument, the effort required for integration into the manufacturing process can be significantly reduced. For this purpose, investigations were carried out during the production of test specimens composed of glass fiber-reinforced polyurethane resin. Specifically, a phased array ultrasonic probe was used to record individual line scans over the form filling time. Taking into account the specifications of the probe used in these experiments, an area of 48.45 mm was inspected with a spatial resolution of 0.85 mm derived from the pitch. Due to the aperture that had to be applied to improve the signal-to-noise ratio, an averaging of the measured values similar to a moving average over a window of 6.8 mm had to be considered. By varying the orientation of the phased array probe and therefore the orientation of the line scans, it is possible to determine the local flow velocities of the matrix system during mold filling. Furthermore, process simulation studies with locally varying fiber volume contents were carried out. Despite the locally limited measuring range of the monitoring method presented, conclusions about the global flow behavior in a large mold can be drawn by comparing the experimentally determined results with the process simulation studies. The agreement between the measurement and simulation was thus improved by around 70%.

Schlagwörter

Stichwörter der Autor:innen

HP-RTMflow front monitoringflow simulationinline measurementprocess optimizationthick-walled compositeultrasonic testing

Autor:innen und Institutionen

  • Institut für Kunststofftechnik (IKT), University of Stuttgart, 70569 Stuttgart, Germany.
  • Institute of Lightweight Engineering and Polymer Technology (ILK), Dresden University of Technology, 01307 Dresden, Germany.

ORCID-Profile: Eckart Kunze, Maik Gude

Förderung

  • Deutsche Forschungsgemeinschaft
  • Deutsche Forschungsgemeinschaft e.V. (DFG)

Zitieren

APA

Littner, L., Protz, R., Kunze, E., Bernhardt, Y., Kreutzbruck, M., & Gude, M. (2023). Flow Front Monitoring in High-Pressure Resin Transfer Molding Using Phased Array Ultrasonic Testing to Optimize Mold Filling Simulations. Materials, 17(1), 207. https://doi.org/10.3390/ma17010207

Vancouver

Littner L, Protz R, Kunze E, Bernhardt Y, Kreutzbruck M, Gude M. Flow Front Monitoring in High-Pressure Resin Transfer Molding Using Phased Array Ultrasonic Testing to Optimize Mold Filling Simulations. Materials. 2023;17(1):207. doi:10.3390/ma17010207

BibTeX
@article{Littner2023,
  author = {Littner, Linus and Protz, Richard and Kunze, Eckart and Bernhardt, Yannick and Kreutzbruck, Marc and Gude, Maik},
  title = {Flow Front Monitoring in High-Pressure Resin Transfer Molding Using Phased Array Ultrasonic Testing to Optimize Mold Filling Simulations},
  journal = {Materials},
  year = {2023},
  volume = {17},
  number = {1},
  pages = {207},
  doi = {10.3390/ma17010207}
}
Kostenlos starten →