EUVIMEDEUVIMED entdecken
ÜbersichtsarbeitOpen Access · CC BY 4.0

Screw Osteointegration—Increasing Biomechanical Resistance to Pull-Out Effect

Bogdan Costăchescu, Adelina-Gabriela Niculescu iD, Alexandru Mihai Grumezescu iD, Daniel Mihai Teleanu

Materials · 11.08.2023 · 16 (16) · 5582

DOI: 10.3390/ma16165582 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Materials, online erschienen am 11.08.2023. Verfasst von Bogdan Costăchescu und 3 weiteren Autor:innen. Beteiligte Einrichtung: "Gr. T. Popa" University of Medicine and Pharmacy, 700115 Iasi, Romania. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 81 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Spinal disorders cover a broad spectrum of pathologies and are among the most prevalent medical conditions. The management of these health issues was noted to be increasingly based on surgical interventions. Spinal fixation devices are often employed to improve surgery outcomes, increasing spinal stability, restoring structural integrity, and ensuring functionality. However, most of the currently used fixation tools are fabricated from materials with very different mechanical properties to native bone that are prone to pull-out effects or fail over time, requiring revision procedures. Solutions to these problems presently exploited in practice include the optimal selection of screw shape and size, modification of insertion trajectory, and utilization of bone cement to reinforce fixation constructs. Nevertheless, none of these methods are without risks and limitations. An alternative option to increasing biomechanical resistance to the pull-out effect is to tackle bone regenerative capacity and focus on screw osteointegration properties. Osteointegration was reportedly enhanced through various optimization strategies, including use of novel materials, surface modification techniques (e.g., application of coatings and topological optimization), and utilization of composites that allow synergistic effects between constituents. In this context, this paper takes a comprehensive path, starting with a brief presentation of spinal fixation devices, moving further to observations on how the pull-out strength can be enhanced with existing methods, and further focusing on techniques for implant osteointegration improvement.

Schlagwörter

Stichwörter der Autor:innen

bone fixationmaterial optimizationosteointegrationpull-out effectreinforcement strategiesspinal fixation devicesspinal screws

Autor:innen und Institutionen

  • "Gr. T. Popa" University of Medicine and Pharmacy, 700115 Iasi, Romania.
  • "Prof. Dr. N. Oblu" Emergency Clinical Hospital, 700309 Iasi, Romania.
  • Research Institute of the University of Bucharest-ICUB, University of Bucharest, 050657 Bucharest, Romania.
  • Department of Science and Engineering of Oxide Materials and Nanomaterials, Politehnica University of Bucharest, 011061 Bucharest, Romania.
  • Academy of Romanian Scientists, Ilfov No. 3, 050044 Bucharest, Romania.
  • "Carol Davila" University of Medicine and Pharmacy, 050474 Bucharest, Romania.

ORCID-Profile: Adelina-Gabriela Niculescu, Alexandru Mihai Grumezescu

Zitieren

APA

Costăchescu, B., Niculescu, A. G., Grumezescu, A. M., & Teleanu, D. M. (2023). Screw Osteointegration—Increasing Biomechanical Resistance to Pull-Out Effect. Materials, 16(16), 5582. https://doi.org/10.3390/ma16165582

Vancouver

Costăchescu B, Niculescu AG, Grumezescu AM, Teleanu DM. Screw Osteointegration—Increasing Biomechanical Resistance to Pull-Out Effect. Materials. 2023;16(16):5582. doi:10.3390/ma16165582

BibTeX
@article{Costchescu2023,
  author = {Costăchescu, Bogdan and Niculescu, Adelina-Gabriela and Grumezescu, Alexandru Mihai and Teleanu, Daniel Mihai},
  title = {Screw Osteointegration—Increasing Biomechanical Resistance to Pull-Out Effect},
  journal = {Materials},
  year = {2023},
  volume = {16},
  number = {16},
  pages = {5582},
  doi = {10.3390/ma16165582}
}
Kostenlos starten →