Study on Porosity Defect Detection in Narrow Gap Laser Welding Based on Spectral Diagnosis
Materials · 13.07.2023 · 16 (14) · 4989
DOI: 10.3390/ma16144989 ↗Kurz gefasst
Fachartikel in der Zeitschrift Materials, online erschienen am 13.07.2023. Verfasst von Jinping Liu und 8 weiteren Autor:innen. Beteiligte Einrichtung: China Nuclear Industry 23 Construction Co., Ltd., Nuclear Industry Research and Engineering Co., Ltd., China National Nuclear Corporation Key Laborat…. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, China Postdoctoral Science Foundation, the National Natural Science Foundation of China.
Abstract (Originalsprache)
As an advanced connection technology for large thick-walled components, narrow gap laser welding has the advantages of small heat input and high efficiency and quality. However, porosity defects are prone to occur inside the weld due to the complex welding environment. In this study, the influence of the process parameters and pollutants such as water and oil on the porosity defect were explored. The action mechanism of water on the electron temperature and spectral intensity of the laser-induced plasma was analyzed. The results showed that the spectral intensity during narrow gap laser welding was weaker than that of flat plate butt welding. Under the optimal welding process conditions, the electron temperature during narrow gap laser self-fusion welding was calculated as 7413.3 K by the Boltzmann plot method. The electron density was 5.6714 × 1015 cm−3, conforming to the thermodynamic equilibrium state. With six groups of self-fusion welding parameters, only sporadic porosity defects were observed according to the X-ray detection. When there was water on the base metal surface, a large number of dense pores were observed on the weld surface and in the weld through X-ray inspection. Compared with the spectral data obtained under the normal process, the relative light intensity of the spectrometer in the whole band was reduced. The electron temperature decreased to the range of 6900 to 7200 K, while the electron density increased. The spectrum variation during narrow gap laser wire filling welding was basically the same as that of laser self-fusion welding. The porosity defects caused by water and oil pollutants in the laser welding could be effectively identified based on the intensity of the Fe I spectral lines.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- China Nuclear Industry 23 Construction Co., Ltd., Nuclear Industry Research and Engineering Co., Ltd., China National Nuclear Corporation Key Laboratory of High Efficiency Welding, Beijing 101300, China.
- Fujian Fuqing Nuclear Power Co., Ltd., Fuzhou 350318, China.
- Tianjin Key Laboratory of Advanced Joining Technology, School of Materials Science and Engineering, Tianjin University, Tianjin 300350, China.
- School of Electrical and Information Engineering, Tianjin University, Tianjin 300072, China.
Förderung
- National Natural Science Foundation of China
- China Postdoctoral Science Foundation
- the National Natural Science Foundation of China
- the China Postdoctoral Science Foundation
Zitieren
APA
Liu, J., Xu, B., Feng, Y., Chen, P., Yan, C., Li, Z., Yang, K., She, K., & Huang, Y. (2023). Study on Porosity Defect Detection in Narrow Gap Laser Welding Based on Spectral Diagnosis. Materials, 16(14), 4989. https://doi.org/10.3390/ma16144989
Vancouver
Liu J, Xu B, Feng Y, Chen P, Yan C, Li Z, et al. Study on Porosity Defect Detection in Narrow Gap Laser Welding Based on Spectral Diagnosis. Materials. 2023;16(14):4989. doi:10.3390/ma16144989
BibTeX
@article{Liu2023,
author = {Liu, Jinping and Xu, Baoping and Feng, Yingchao and Chen, Peng and Yan, Cancan and Li, Zhuyuan and Yang, Kaisong and She, Kun and Huang, Yiming},
title = {Study on Porosity Defect Detection in Narrow Gap Laser Welding Based on Spectral Diagnosis},
journal = {Materials},
year = {2023},
volume = {16},
number = {14},
pages = {4989},
doi = {10.3390/ma16144989}
}