EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Fracture Toughness and Fatigue Crack Growth Analyses on a Biomedical Ti-27Nb Alloy under Constant Amplitude Loading Using Extended Finite Element Modelling

Mohammed Y Abdellah iD, Hamzah Alharthi iD

Materials · 19.06.2023 · 16 (12) · 4467

DOI: 10.3390/ma16124467 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Materials, online erschienen am 19.06.2023. Verfasst von Mohammed Y Abdellah und 1 weiteren Autor:innen. Beteiligte Einrichtung: Mechanical Engineering Department, Faculty of Engineering, South Valley University, Qena 83523, Egypt. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 70 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The human body normally uses alternative materials such as implants to replace injured or damaged bone. Fatigue fracture is a common and serious type of damage in implant materials. Therefore, a deep understanding and estimation or prediction of such loading modes, which are influenced by many factors, is of great importance and attractiveness. In this study, the fracture toughness of Ti-27Nb, a well-known implant titanium alloy biomaterial, was simulated using an advanced finite element subroutine. Furthermore, a robust direct cyclic finite element fatigue model based on a fatigue failure criterion derived from Paris’ law is used in conjunction with an advanced finite element model to estimate the initiation of fatigue crack growth in such materials under ambient conditions. The R-curve was fully predicted, yielding a minimum percent error of less than 2% for fracture toughness and less than 5% for fracture separation energy. This provides a valuable technique and data for fracture and fatigue performance of such bio-implant materials. Fatigue crack growth was predicted with a minimum percent difference of less than nine for compact tensile test standard specimens. The shape and mode of material behaviour have a significant effect on the Paris law constant. The fracture modes showed that the crack path is in two directions. The finite element direct cycle fatigue method was recommended to determine the fatigue crack growth of biomaterials.

Schlagwörter

Stichwörter der Autor:innen

J-integralXFEMbiomaterialbonefracture toughnessimplant

Autor:innen und Institutionen

  • Mechanical Engineering Department, Faculty of Engineering, South Valley University, Qena 83523, Egypt.
  • Mechanical Engineering Department, College of Engineering and Islamic Architecture, Umm Al-Qura University, Makkah 24382, Saudi Arabia.

ORCID-Profile: Mohammed Y Abdellah, Hamzah Alharthi

Zitieren

APA

Abdellah, M. Y., & Alharthi, H. (2023). Fracture Toughness and Fatigue Crack Growth Analyses on a Biomedical Ti-27Nb Alloy under Constant Amplitude Loading Using Extended Finite Element Modelling. Materials, 16(12), 4467. https://doi.org/10.3390/ma16124467

Vancouver

Abdellah MY, Alharthi H. Fracture Toughness and Fatigue Crack Growth Analyses on a Biomedical Ti-27Nb Alloy under Constant Amplitude Loading Using Extended Finite Element Modelling. Materials. 2023;16(12):4467. doi:10.3390/ma16124467

BibTeX
@article{Abdellah2023,
  author = {Abdellah, Mohammed Y and Alharthi, Hamzah},
  title = {Fracture Toughness and Fatigue Crack Growth Analyses on a Biomedical Ti-27Nb Alloy under Constant Amplitude Loading Using Extended Finite Element Modelling},
  journal = {Materials},
  year = {2023},
  volume = {16},
  number = {12},
  pages = {4467},
  doi = {10.3390/ma16124467}
}