Multi-Scale Topology Optimization of Femoral Stem Structure Subject to Stress Shielding Reduce
Materials · 17.04.2023 · 16 (8) · 3151
DOI: 10.3390/ma16083151 ↗Kurz gefasst
Fachartikel in der Zeitschrift Materials, online erschienen am 17.04.2023. Verfasst von Zhongmin Xiao und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Mechanical and Electrical Engineering, Guangzhou University, Guangzhou 510006, China. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Guangzhou City School Joint Project, University Scientific Research Project of Eduction Bureau of Guangzhou Municipality.
Abstract (Originalsprache)
Hip replacement femoral implants are made of substantial materials that all have stiffness considerably higher than that of bone, which can cause significant bone resorption secondary to stress shielding and lead to severe complications. The topology optimization design method based on the uniform distribution of material micro-structure density can form a continuous mechanical transmission route, which can better solve the problem of reducing the stress shielding effect. A multi-scale parallel topology optimization method is proposed in this paper and a topological structure of type B femoral stem is derived. Using the traditional topology optimization method (Solid Isotropic Material with Penalization, SIMP), a topological structure of type A femoral stem is also derived. The sensitivity of the two kinds of femoral stems to the change of load direction is compared with the variation amplitude of the structural flexibility of the femoral stem. Furthermore, the finite element method is used to analyze the stress of type A and type B femoral stem under multiple conditions. Simulation and experimental results show that the average stress of type A and type B femoral stem on the femur are 14.80 MPa, 23.55 MPa, 16.94 MPa and 10.89 MPa, 20.92 MPa, 16.50 MPa, respectively. For type B femoral stem, the average error of strain is −1682με and the average relative error is 20.3% at the test points on the medial side and the mean error of strain is 1281με and the mean relative error is 19.5% at the test points on the outside.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Mechanical and Electrical Engineering, Guangzhou University, Guangzhou 510006, China.
ORCID-Profile: Dachang Zhu
Förderung
- Guangzhou City School Joint Project
- University Scientific Research Project of Eduction Bureau of Guangzhou Municipality
Zitieren
APA
Xiao, Z., Wu, L., Wu, W., Tang, R., Dai, J., & Zhu, D. (2023). Multi-Scale Topology Optimization of Femoral Stem Structure Subject to Stress Shielding Reduce. Materials, 16(8), 3151. https://doi.org/10.3390/ma16083151
Vancouver
Xiao Z, Wu L, Wu W, Tang R, Dai J, Zhu D. Multi-Scale Topology Optimization of Femoral Stem Structure Subject to Stress Shielding Reduce. Materials. 2023;16(8):3151. doi:10.3390/ma16083151
BibTeX
@article{Xiao2023,
author = {Xiao, Zhongmin and Wu, Longfei and Wu, Wenqiang and Tang, Ruizhi and Dai, Jietao and Zhu, Dachang},
title = {Multi-Scale Topology Optimization of Femoral Stem Structure Subject to Stress Shielding Reduce},
journal = {Materials},
year = {2023},
volume = {16},
number = {8},
pages = {3151},
doi = {10.3390/ma16083151}
}
EUVIMED