Fachartikel in der Zeitschrift Materials, online erschienen am 14.04.2023. Verfasst von Dennis Schönfeld und 5 weiteren Autor:innen. Beteiligte Einrichtung: Fraunhofer Institute for Applied Polymer Research IAP, Geiselbergstr. 69, 14476 Potsdam, Germany. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 75 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Federal Ministry for Economic Affairs and Energy, Federal Ministry for Economic Affairs and Climate Action (BMWK).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aligner therapy for orthodontic tooth movement is gaining importance in orthodontics. The aim of this contribution is to introduce a thermo- and water-responsive shape memory polymer (SMP), which could lay the foundation for a new type of aligner therapy. The thermal, thermo-mechanical, and shape memory properties of thermoplastic polyurethane were studied by means of differential scanning calorimetry (DSC), dynamic mechanical analysis (DMA), and various practical experiments. The glass transition temperature of the SMP relevant for later switching was determined to be 50 °C in the DSC, while the tan δ peak was detected at 60 °C in the DMA. A biological evaluation was carried out using mouse fibroblast cells, which showed that the SMP is not cytotoxic in vitro. On a digitally designed and additively manufactured dental model, four aligners were fabricated from an injection-molded foil using a thermoforming process. The aligners were then heated and placed on a second denture model which had a malocclusion. After cooling, the aligners were in a programmed shape. The movement of a loose, artificial tooth and thus the correction of the malocclusion could be realized by thermal triggering the shape memory effect, at which the aligner corrected a displacement with an arc length of approximately 3.5 mm. The developed maximum force was separately determined to be about 1 N. Moreover, shape recovery of another aligner was realized within 20 h in 37 °C water. In perspective, the present approach can help to reduce the number of orthodontic aligners in therapy and thus avoid excessive material waste.

Schlagwörter

Stichwörter der Autor:innen

aligner therapyshape memory polymerthermo-responsivethermoplastic polyurethanewater-responsive

Autor:innen und Institutionen

  • Fraunhofer Institute for Applied Polymer Research IAP, Geiselbergstr. 69, 14476 Potsdam, Germany.
  • Department of Orthodontics, Universitätsklinikum Düsseldorf, Moorenstr. 5, 40225 Düsseldorf, Germany.

ORCID-Profile: Thorsten Pretsch

Förderung

  • Federal Ministry for Economic Affairs and Energy
  • Federal Ministry for Economic Affairs and Climate Action (BMWK)

Zitieren

APA

Schönfeld, D., Koss, S., Vohl, N., Friess, F., Drescher, D., & Pretsch, T. (2023). Dual Stimuli-Responsive Orthodontic Aligners: An In Vitro Study. Materials, 16(8), 3094. https://doi.org/10.3390/ma16083094

Vancouver

Schönfeld D, Koss S, Vohl N, Friess F, Drescher D, Pretsch T. Dual Stimuli-Responsive Orthodontic Aligners: An In Vitro Study. Materials. 2023;16(8):3094. doi:10.3390/ma16083094

BibTeX
@article{Schnfeld2023,
  author = {Schönfeld, Dennis and Koss, Samantha and Vohl, Nils and Friess, Fabian and Drescher, Dieter and Pretsch, Thorsten},
  title = {Dual Stimuli-Responsive Orthodontic Aligners: An In Vitro Study},
  journal = {Materials},
  year = {2023},
  volume = {16},
  number = {8},
  pages = {3094},
  doi = {10.3390/ma16083094}
}
Kostenlos starten →