Fachartikel in der Zeitschrift Clinical Oral Investigations, online erschienen am 19.04.2024. Verfasst von Tarek M Elshazly und 8 weiteren Autor:innen. Beteiligte Einrichtung: Oral Technology, Dental School, University Hospital Bonn, Welschnonnenstr. 17, Bonn, 53111, Germany. tarek.m.elshazly@gmail.com. Hauptthemen laut MEDLINE: Orthodontic Appliance Design, Tooth Movement Techniques. Die Arbeit wurde bisher 32-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universitätsklinikum Bonn.
Abstract (Originalsprache)
Objectives
To investigate the effects of material type and thickness on force generation and distribution by aligners. Materials and methods Sixty aligners were divided into six groups ( n = 10): one group with a thickness of 0.89 mm using Zendura Viva (Multi-layer), four groups with a thickness of 0.75 mm using Zendura FLX (Multi-layer), CA Pro (Multi-layer), Zendura (Single-layer), and Duran (Single-layer) sheets, and one group with a thickness of 0.50 mm using Duran sheets. Force measurements were conducted using Fuji® pressure-sensitive films.
Results
The lowest force values, both active and passive, were recorded for the multi-layered sheets: CA Pro (83.1 N, 50.5 N), Zendura FLX (88.9 N, 60.7 N), and Zendura Viva (92.5 N, 68.5 N). Conversely, the highest values were recorded for the single-layered sheets: Duran (131.9 N, 71.8 N) and Zendura (149.7 N, 89.8 N). The highest force was recorded at the middle third of the aligner, followed by the incisal third, and then the cervical third. The net force between the incisal and cervical thirds (F I -F C ) showed insignificant difference across different materials. However, when comparing the incisal and middle thirds, the net force (F I -F M ) was higher with single-layered materials. Both overall force and net force (F I -F M ) were significantly higher with 0.75 mm compared to those with a thickness of 0.50 mm.
Conclusions
Multi-layered aligner materials exert lower forces compared to their single-layered counterparts. Additionally, increased thickness in aligners results in enhanced retention and greater force generation. For effective bodily tooth movement, thicker and single-layered rigid materials are preferred. Clinical relevance This research provides valuable insights into the biomechanics of orthodontic aligners, which could have significant clinical implications for orthodontists. Orthodontists might use this information to more effectively tailor aligner treatments, considering the specific tooth movement required for each individual patient. In light of these findings, an exchangeable protocol for aligner treatment is suggested, which however needs to be proven clinically. This protocol proposes alternating between multi-layered and single-layered materials within the same treatment phase. This strategy is suggested to optimize treatment outcomes, particularly when planning for a bodily tooth movement.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Oral Technology, Dental School, University Hospital Bonn, Welschnonnenstr. 17, Bonn, 53111, Germany. tarek.m.elshazly@gmail.com.
- Oral Technology, Dental School, University Hospital Bonn, Welschnonnenstr. 17, Bonn, 53111, Germany.
- Biomaterials Department, Faculty of Dentistry, Ain Shams University, Cairo, Egypt.
- Institut Straumann AG, Basel, Switzerland.
- Orthodontic Department, Faculty of Dentistry, Suez Canal University, Ismailia, Egypt.
- Department of Dental Health, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia.
ORCID-Profile: Tarek M Elshazly
Förderung
- Universitätsklinikum Bonn
Zitieren
APA
Elshazly, T. M., Bourauel, C., Ismail, A., Ghoraba, O., Aldesoki, M., Salvatori, D., Elattar, H., Alhotan, A., & Alkabani, Y. (2024). Effect of material composition and thickness of orthodontic aligners on the transmission and distribution of forces: an in vitro study. Clinical Oral Investigations, 28(5). https://doi.org/10.1007/s00784-024-05662-x
Vancouver
Elshazly TM, Bourauel C, Ismail A, Ghoraba O, Aldesoki M, Salvatori D, et al. Effect of material composition and thickness of orthodontic aligners on the transmission and distribution of forces: an in vitro study. Clinical Oral Investigations. 2024;28(5). doi:10.1007/s00784-024-05662-x
BibTeX
@article{Elshazly2024,
author = {Elshazly, Tarek M and Bourauel, Christoph and Ismail, Ahmed and Ghoraba, Omar and Aldesoki, Mostafa and Salvatori, Damiano and Elattar, Hanaa and Alhotan, Abdulaziz and Alkabani, Yasmine},
title = {Effect of material composition and thickness of orthodontic aligners on the transmission and distribution of forces: an in vitro study},
journal = {Clinical Oral Investigations},
year = {2024},
volume = {28},
number = {5},
doi = {10.1007/s00784-024-05662-x}
}
EUVIMED