Abstract (Originalsprache)

This computational study examines whether a published optical calibration identifies mechanical parameters and supports a unique design recommendation for a dual fiber Bragg grating (FBG) cantilever–spring displacement sensor. Within the adopted series compliance model, the 39.47 pm/mm sensitivity identifies the product of strain transfer and equivalent stiffness. The same anchor admits K = 71.969–91.228 N/m for η = 0.80–1.00. A counterexample extracted from archived nonlinear results shows that η = 0.9500 and 0.9595, with compatible reference stiffnesses of 75.979 and 75.183 N/m, retain only Selected 2 and Selected 3, respectively, across four declared tip geometries under unchanged constraints. Thus, the calibration does not identify a robust choice among the five retained candidates within this family. Selected 2’s nominal 43.07% nonlinearity reduction costs 23.54% more force. Retrospective published optical cycles give a fixed zero root mean square error (RMSE) of 153.6 pm on 37 recovered markers; coordinate and ruler uncertainty preclude hardware accuracy claims. Existing finite element, uncertainty, thermal, bonding and wavelength allocation analyses provide supporting conditional assessments. The contribution is a sensor-specific demonstration of which mechanical and design conclusions remain underdetermined by the adopted calibration. Independent physical validation remains necessary for predictive hardware claims.

Zitieren

APA

Bazarbay, A., Kadyrova, R., Mussapirova, G., Yerkeldessova, G., Mamatova, G., Sabibolda, A., Smailov, N., & Yeleuova, A. (2026). Calibration Identifiability and Conditional Design Choices for a Dual-FBG Displacement Sensor. Journal of Sensor and Actuator Networks, 15(6), 90. https://doi.org/10.3390/jsan15060090

Vancouver

Bazarbay A, Kadyrova R, Mussapirova G, Yerkeldessova G, Mamatova G, Sabibolda A, et al. Calibration Identifiability and Conditional Design Choices for a Dual-FBG Displacement Sensor. Journal of Sensor and Actuator Networks. 2026;15(6):90. doi:10.3390/jsan15060090

BibTeX
@article{Bazarbay2026,
  author = {Bazarbay, Aidana and Kadyrova, Rashida and Mussapirova, Gulzada and Yerkeldessova, Gulzada and Mamatova, Gulnar and Sabibolda, Akezhan and Smailov, Nurzhigit and Yeleuova, Ardak},
  title = {Calibration Identifiability and Conditional Design Choices for a Dual-FBG Displacement Sensor},
  journal = {Journal of Sensor and Actuator Networks},
  year = {2026},
  volume = {15},
  number = {6},
  pages = {90},
  doi = {10.3390/jsan15060090}
}
Kostenlos starten →