Short Expandable-Wing Suture Anchors for Tibial Eminence Avulsion Fracture Fixation: Effects of Solid Versus Additively Manufactured Lattice Wings on Biomechanical Performance and Cytocompatibility
Journal of Functional Biomaterials · 18.11.2026 · 17 (11) · 584
DOI: 10.3390/jfb17110584 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Functional Biomaterials, online erschienen am 18.11.2026. Verfasst von Chia-Hung Tsai und 6 weiteren Autor:innen. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Science and Technology Council.
Abstract (Originalsprache)
Fixation of tibial eminence avulsion fractures (TEAFs) in skeletally immature patients requires adequate mechanical stability within a limited insertion depth to minimize the risk of physeal injury. Conventional transosseous cortical-button fixation (TCBF) requires the creation of tibial bone tunnels, whereas conventional suture anchors may have excessive insertion depths. In our previous study, a short expandable-wing (SEW) suture anchor (9.5 mm in length and 5.5 mm in diameter) with CNC-machined solid wings was developed to enhance fixation strength within a limited bone volume. In the present study, a second-generation SEW anchor was developed by replacing the solid wings with 3D-printed Ti6Al4V lattice wings to provide a potentially more favorable bone–implant interface. The mechanical performance of CNC-SEW and metal additively manufactured SEW (MAM-SEW) anchors was evaluated using polyurethane-block pull-out testing and a porcine TEAF model with single- and double-suture TCBF controls. Cytocompatibility was assessed using an MG-63 direct-contact MTT assay. Pull-out loads were 574.8 ± 10.6 N for CNC-SEW and 501.2 ± 39.2 N for MAM-SEW, compared with 429.0 ± 29.0 N for a historical TWINFIX comparator. After 200 loading cycles in the porcine model, cumulative displacements were 0.9 and 0.7 mm for CNC-SEW and MAM-SEW, respectively, compared with 2.2 and 1.3 mm for single- and double-suture TCBF. The corresponding ultimate failure loads were 278.88 and 292.56 N for the SEW groups, compared with 109.86 and 223.56 N for the TCBF groups. The MAM-SEW group also exhibited higher MG-63 metabolic activity than the CNC-SEW group. These findings demonstrate favorable initial fixation performance and preliminary cytocompatibility of the lattice-wing SEW anchor, supporting its potential application in TEAF fixation. Further studies are required to evaluate long-term osseointegration and physeal safety.
Förderung
- National Science and Technology Council
Zitieren
APA
Tsai, C., Lin, H., Wang, H., Cheng, Y., Chang, C., Lin, R., & Lin, C. (2026). Short Expandable-Wing Suture Anchors for Tibial Eminence Avulsion Fracture Fixation: Effects of Solid Versus Additively Manufactured Lattice Wings on Biomechanical Performance and Cytocompatibility. Journal of Functional Biomaterials, 17(11), 584. https://doi.org/10.3390/jfb17110584
Vancouver
Tsai C, Lin H, Wang H, Cheng Y, Chang C, Lin R, et al. Short Expandable-Wing Suture Anchors for Tibial Eminence Avulsion Fracture Fixation: Effects of Solid Versus Additively Manufactured Lattice Wings on Biomechanical Performance and Cytocompatibility. Journal of Functional Biomaterials. 2026;17(11):584. doi:10.3390/jfb17110584
BibTeX
@article{Tsai2026,
author = {Tsai, Chia-Hung and Lin, Hsu-Wei and Wang, Hsuan-Wen and Cheng, Yen and Chang, Chiao-Min and Lin, Rong-Chen and Lin, Chun-Li},
title = {Short Expandable-Wing Suture Anchors for Tibial Eminence Avulsion Fracture Fixation: Effects of Solid Versus Additively Manufactured Lattice Wings on Biomechanical Performance and Cytocompatibility},
journal = {Journal of Functional Biomaterials},
year = {2026},
volume = {17},
number = {11},
pages = {584},
doi = {10.3390/jfb17110584}
}
EUVIMED