Comparing Biomechanical Properties of Bioabsorbable Suture Anchors: A Comprehensive Review
Biomimetics · 12.03.2025 · 10 (3) · 175
DOI: 10.3390/biomimetics10030175 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Biomimetics, online erschienen am 12.03.2025. Verfasst von Dorien I Schonebaum und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Plastic and Reconstructive Surgery, Harvard Medical School, Beth Israel Deaconess Medical Center, Boston, MA 02215, USA. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 62 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Suture anchors (SAs) are medical devices used to connect soft tissue to bone. Traditionally these were made of metal; however, in the past few decades, bio-absorbable suture anchors have been created to overcome revision surgeries and other complications caused by metallic SAs. This systematic review aims to analyze the biomechanical properties of these SAs to gain a better understanding of their safety and utilization. A comprehensive systematic review that adhered to the PRISMA guidelines was conducted. Primary outcomes were that the pull-out strength of SAs, the rate of degradation secondarily, and the biocompatibility of all SAs were analyzed. After screening 347 articles, 16 were included in this review. These studies revealed that the pull-out strength of bio-absorbable SAs was not inferior to that of their non-absorbable comparatives. The studies also revealed that the rate of degradation varies widely from 7 to 90 months. It also showed that not all absorbable SAs were fully absorbed within the expected timeframe. This systematic review demonstrates that existing suture anchor materials exhibit comparable pull-out strengths, material-specific degradation rates, and variable biocompatibility. All-suture anchors had promising results in biocompatibility, but evidence fails to identify a single most favorable material. Higher-powered studies that incorporate tissue-specific characteristics, such as rotator cuff tear size, are warranted. To meet demonstrated shortcomings in strength and biocompatibility, we propose silk fibroin as a novel material for suture anchor design for its customizable properties and superior strength.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Plastic and Reconstructive Surgery, Harvard Medical School, Beth Israel Deaconess Medical Center, Boston, MA 02215, USA.
- Department of Plastic and Reconstructive Surgery, Amsterdam UMC, 1105 AZ Amsterdam, The Netherlands.
- Department of Plastic and Reconstructive Surgery, University of Minnesota, Minneapolis, MN 55455, USA.
- Department of Biomedical Engineering, Tufts University, Medford, MA 02155, USA.
ORCID-Profile: Maria J Escobar-Domingo, Sasha Wood, Jade E Smith, David L Kaplan
Zitieren
APA
Schonebaum, D. I., Garbaccio, N., Escobar-Domingo, M. J., Wood, S., Smith, J. E., Foster, L., Mehdizadeh, M., Cordero, J. J., Foppiani, J. A., Choudry, U., Kaplan, D. L., & Lin, S. J. (2025). Comparing Biomechanical Properties of Bioabsorbable Suture Anchors: A Comprehensive Review. Biomimetics, 10(3), 175. https://doi.org/10.3390/biomimetics10030175
Vancouver
Schonebaum DI, Garbaccio N, Escobar-Domingo MJ, Wood S, Smith JE, Foster L, et al. Comparing Biomechanical Properties of Bioabsorbable Suture Anchors: A Comprehensive Review. Biomimetics. 2025;10(3):175. doi:10.3390/biomimetics10030175
BibTeX
@article{Schonebaum2025,
author = {Schonebaum, Dorien I and Garbaccio, Noelle and Escobar-Domingo, Maria J and Wood, Sasha and Smith, Jade E and Foster, Lacey and Mehdizadeh, Morvarid and Cordero, Justin J and Foppiani, Jose A and Choudry, Umar and Kaplan, David L and Lin, Samuel J},
title = {Comparing Biomechanical Properties of Bioabsorbable Suture Anchors: A Comprehensive Review},
journal = {Biomimetics},
year = {2025},
volume = {10},
number = {3},
pages = {175},
doi = {10.3390/biomimetics10030175}
}
EUVIMED