Bone–Screw–Force Interactions in Palatal Orthodontic Mini-Implants: A Scoping Review and Decision Framework for Primary Stability and Biomechanically Driven Site Selection
Journal of Functional Biomaterials · 26.07.2026 · 17 (8) · 360
DOI: 10.3390/jfb17080360 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Journal of Functional Biomaterials, online erschienen am 26.07.2026. Verfasst von Mahmoud Elsaafin und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthodontics, Faculty of Dental Medicine, George Emil Palade University of Medicine, Pharmacy, Science, and Technology of Târgu Mureș, …. Die Arbeit nennt 426 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Palatal orthodontic mini-implants are increasingly used for sagittal, vertical, and transverse mechanics, including molar distalization, mesialization, posterior intrusion, impacted tooth traction, and miniscrew-assisted rapid palatal expansion. Yet site selection is often discussed as if anatomical bone availability were the dominant determinant of performance.
Objective
This scoping review maps direct palatal evidence and supporting mechanistic evidence on how palatal substrate, miniscrew design, insertion protocol, digital planning, biomaterial surface, and biomechanical loading interact to determine primary stability, loaded stability, survival, and failure risk.
Methods
Records were searched in PubMed/MEDLINE, Scopus and Web of Science Core Collection and organized into two evidence streams, as follows: P1 direct palatal evidence and P2 supporting mechanistic/biomaterials evidence. Data were charted using a Bone–Screw–Force framework.
Results
The evidence indicates that anterior palatal and anterior paramedian sites are usually favorable for routine anchorage, but posterior sites, PPSAIS, and MARPE locations may warrant patient-specific three-dimensional assessment when clinical and conventional radiographic evaluation is insufficient. Primary stability emerges from cortical thickness, trabecular quality, effective intraosseous length, miniscrew diameter, thread design, insertion angle, pilot-hole protocol, torque, force magnitude, and biological response. Digital workflows are best interpreted as trajectory-control technologies rather than as convenience tools. Biomaterial and surface evidence remains promising but insufficiently connected to palatal-specific outcomes.
Conclusions
Palatal miniscrew performance should be reframed as an interface problem rather than a site-only problem. A Bone–Screw–Force framework can support biomechanically driven site selection while identifying where quantitative evidence remains insufficient.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthodontics, Faculty of Dental Medicine, George Emil Palade University of Medicine, Pharmacy, Science, and Technology of Târgu Mureș, 38 Gh. Marinescu Str., 540142 Târgu Mureș, Romania.
- Department of Odontology and Oral Pathology, George Emil Palade University of Medicine, Pharmacy, Science, and Technology of Târgu Mureș, 540139 Târgu Mureș, Romania.
- Department of Orthodontics and Dentofacial Orthopedics, Faculty of Dental Medicine, Titu Maiorescu University, 67A Gheorghe Petrașcu Street, 031593 Bucharest, Romania.
- Department of Oral and Maxillofacial Surgery, Faculty of Dental Medicine, George Emil Palade University of Medicine, Pharmacy, Science, and Technology of Târgu Mureș, 38 Gheorghe Marinescu Street, 540139 Târgu Mureș, Ro…
- Department of Preventive and Community Dentistry, Faculty of Dental Medicine, George Emil Palade University of Medicine, Pharmacy, Science, and Technology of Târgu Mureș, 38 Gheorghe Marinescu Street, 540139 Târgu Mureș…
- Department of Plastic Surgery and Reconstructive Microsurgery, Târgu Mureș County Emergency Clinical Hospital, 50 Gheorghe Marinescu Street, 540136 Târgu Mureș, Romania.
ORCID-Profile: Mahmoud Elsaafin, Alexandra Mihaela Stoica, Adina Simona Coșarcă, Liana Bereșescu, Valeriu Mihai But
Zitieren
APA
Elsaafin, M., Stoica, A. M., Mariș, M., Coșarcă, A. S., Bereșescu, L., Elsaafin, A., Păcurar, M., & But, V. M. (2026). Bone–Screw–Force Interactions in Palatal Orthodontic Mini-Implants: A Scoping Review and Decision Framework for Primary Stability and Biomechanically Driven Site Selection. Journal of Functional Biomaterials, 17(8), 360. https://doi.org/10.3390/jfb17080360
Vancouver
Elsaafin M, Stoica AM, Mariș M, Coșarcă AS, Bereșescu L, Elsaafin A, et al. Bone–Screw–Force Interactions in Palatal Orthodontic Mini-Implants: A Scoping Review and Decision Framework for Primary Stability and Biomechanically Driven Site Selection. Journal of Functional Biomaterials. 2026;17(8):360. doi:10.3390/jfb17080360
BibTeX
@article{Elsaafin2026,
author = {Elsaafin, Mahmoud and Stoica, Alexandra Mihaela and Mariș, Marius and Coșarcă, Adina Simona and Bereșescu, Liana and Elsaafin, Ahmed and Păcurar, Mariana and But, Valeriu Mihai},
title = {Bone–Screw–Force Interactions in Palatal Orthodontic Mini-Implants: A Scoping Review and Decision Framework for Primary Stability and Biomechanically Driven Site Selection},
journal = {Journal of Functional Biomaterials},
year = {2026},
volume = {17},
number = {8},
pages = {360},
doi = {10.3390/jfb17080360}
}
EUVIMED