EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte Studie

Artificial intelligence‐assisted determination of available sites for palatal orthodontic mini implants based on palatal thickness through CBCT

Tianjin Tao, Ke Zou, Ruiyi Jiang, Ketai He, Xian He, Mengyun Zhang, Zhouqiang Wu, Xiaojing Shen, Xuedong Yuan, Wenli Lai, Hu Long

Orthodontics & Craniofacial Research · 2023-08 · 26 (3) · 491-499

DOI: 10.1111/ocr.12634 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Orthodontics & Craniofacial Research, online erschienen am 31.01.2023. Verfasst von Tianjin Tao und 10 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases & Department of Orthodontics, West China Hospital of Stom…. Hauptthemen laut MEDLINE: Dental Implants, Spiral Cone-Beam Computed Tomography, Orthodontic Anchorage Procedures. Die Arbeit wurde bisher 22-mal zitiert (Crossref) und nennt 30 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Sichuan Science and Technology Program, CSA Clinical Research Fund.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To develop an artificial intelligence (AI) system for automatic palate segmentation through CBCT, and to determine the personalized available sites for palatal mini implants by measuring palatal bone and soft tissue thickness according to the AI‐predicted results. Materials and Methods Eight thousand four hundred target slices (from 70 CBCT scans) from orthodontic patients were collected, labelled by well‐trained orthodontists and randomly divided into two groups: a training set and a test set. After the deep learning process, we evaluated the performance of our deep learning model with the mean Dice similarity coefficient (DSC), average symmetric surface distance (ASSD), sensitivity (SEN), positive predictive value (PPV) and mean thickness percentage error (MTPE). The pixel traversal method was proposed to measure the thickness of palatal bone and soft tissue, and to predict available sites for palatal orthodontic mini implants. Then, an example of available sites for palatal mini implants from the test set was mapped.

Results

The average DSC, ASSD, SEN, PPV and MTPE for the segmented palatal bone tissue were 0.831%, 1.122%, 0.876%, 0.815% and 6.70%, while that for the palatal soft tissue were 0.741%, 1.091%, 0.861%, 0.695% and 12.2%, respectively. Besides, an example of available sites for palatal mini implants was mapped according to predefined criteria.

Conclusions

Our AI system showed high accuracy for palatal segmentation and thickness measurement, which is helpful for the determination of available sites and the design of a surgical guide for palatal orthodontic mini implants.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dental ImplantsSpiral Cone-Beam Computed TomographyOrthodontic Anchorage ProceduresHumansArtificial IntelligencePalateCone-Beam Computed Tomography

Stichwörter der Autor:innen

artificial intelligencemini-implantspalate

Substanzen

Dental Implants

Autor:innen und Institutionen

  • State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases & Department of Orthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu, China.
  • National Key Laboratory of Fundamental Science on Synthetic Vision, Sichuan University, Chengdu, China.
  • College of Mathematics, Sichuan University, Chengdu, China.
  • College of Computer Science, Sichuan University, Chengdu, China.

Förderung

  • National Natural Science Foundation of China
  • Sichuan Science and Technology Program
  • CSA Clinical Research Fund
  • Research and Develop Program, West China Hospital of Stomatology, Sichuan University

Zitieren

APA

Tao, T., Zou, K., Jiang, R., He, K., He, X., Zhang, M., Wu, Z., Shen, X., Yuan, X., Lai, W., & Long, H. (2023). Artificial intelligence‐assisted determination of available sites for palatal orthodontic mini implants based on palatal thickness through CBCT. Orthodontics & Craniofacial Research, 26(3), 491-499. https://doi.org/10.1111/ocr.12634

Vancouver

Tao T, Zou K, Jiang R, He K, He X, Zhang M, et al. Artificial intelligence‐assisted determination of available sites for palatal orthodontic mini implants based on palatal thickness through CBCT. Orthodontics & Craniofacial Research. 2023;26(3):491-499. doi:10.1111/ocr.12634

BibTeX
@article{Tao2023,
  author = {Tao, Tianjin and Zou, Ke and Jiang, Ruiyi and He, Ketai and He, Xian and Zhang, Mengyun and Wu, Zhouqiang and Shen, Xiaojing and Yuan, Xuedong and Lai, Wenli and Long, Hu},
  title = {Artificial intelligence‐assisted determination of available sites for palatal orthodontic mini implants based on palatal thickness through CBCT},
  journal = {Orthodontics & Craniofacial Research},
  year = {2023},
  volume = {26},
  number = {3},
  pages = {491--499},
  doi = {10.1111/ocr.12634}
}
Kostenlos starten →