EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Influence of Proximal-Cervical Undermined Enamel Areas on Marginal Quality and Enamel Integrity of Laboratory and CAD/CAM Ceramic Inlays and Partial Crowns

Roland Frankenberger iD, Katharina Friedrich, Marie-Christine Dudek, Julia Winter, Norbert Krämer, Matthias J Roggendorf

Journal of Functional Biomaterials · 01.03.2025 · 16 (3) · 82

DOI: 10.3390/jfb16030082 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Functional Biomaterials, online erschienen am 01.03.2025. Verfasst von Roland Frankenberger und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Operative Dentistry, Endodontics, and Pediatric Dentistry, Medical Center for Dentistry, University Medical Center Giessen and Marburg,…. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

(1) The aim of this in vitro study was to investigate the handling of proximal-cervical undermined enamel margins on the adhesive performance of differently fabricated and differently cemented ceramic inlays and partial crowns (2)

Methods

192 extracted third molars received MOD (n = 96) and partial crown (n = 96) preparations. A mesial 2 × 2 × 4 mm cervical groove was created in dentin to simulate a deeper (dentin) caries excavation. This dentin groove was either left (G/groove), filled with composite (F/filling), or completely removed (D/dentin). Distal proximal boxes did not receive a groove and served as controls within the same tooth. Labside (e.max Press) restorations additionally went through a temporary phase. Labside and chairside (e.max CAD) inlays and partial crowns were then adhesively luted with Syntac/Variolink Esthetic (SV) or Adhese Universal/Variolink Esthetic (AV). Initially, and again after thermomechanical loading (TML: 1 million cycles at 50 N, 25,000 thermocycles at 5 °C/55 °C), specimens were molded and the resulting 24 groups of epoxy replicas (n = 8) were gold-sputtered and examined for marginal gaps using scanning electron microscopy (200× magnification). Light microscopy (10× magnification) was used to measure proximal cervical crack propagation in adjacent enamel. (3)

Results

Regardless of the adhesive system, D groups generally showed significantly lower marginal quality (79–88%; p < 0.05), with the universal adhesive performing better than the multi-step adhesive system (p < 0.05). Subgroups G and F were similar in marginal quality (94–98%; p > 0.05) and not worse than the controls (p > 0.05) regardless of the adhesive system, but showed less cracking in F than in G (p < 0.05). In general, fewer cracks were observed in chairside CAD/CAM restorations than in laboratory-fabricated restorations (p < 0.05). Partial crowns showed better marginal quality (96–98%) and less cracking than inlays (p < 0.05). (4)

Conclusions

If the dentin level is lower than the enamel level in ceramic preparations after caries excavation in the proximal box, the resulting undermined enamel should not be removed. In terms of enamel integrity, partial crowns outperformed inlays.

Schlagwörter

Stichwörter der Autor:innen

adhesiveceramiccrackingetch-and-rinseinlaymarginal qualitypartial crownself-etch

Autor:innen und Institutionen

  • Department of Operative Dentistry, Endodontics, and Pediatric Dentistry, Medical Center for Dentistry, University Medical Center Giessen and Marburg, 35039 Marburg, Germany.
  • Department of Paediatric Dentistry, Medical Center for Dentistry, University Medical Center Giessen and Marburg, Campus Giessen, Schlangenzahl 14, 35392 Giessen, Germany.

ORCID-Profile: Roland Frankenberger

Zitieren

APA

Frankenberger, R., Friedrich, K., Dudek, M. C., Winter, J., Krämer, N., & Roggendorf, M. J. (2025). Influence of Proximal-Cervical Undermined Enamel Areas on Marginal Quality and Enamel Integrity of Laboratory and CAD/CAM Ceramic Inlays and Partial Crowns. Journal of Functional Biomaterials, 16(3), 82. https://doi.org/10.3390/jfb16030082

Vancouver

Frankenberger R, Friedrich K, Dudek MC, Winter J, Krämer N, Roggendorf MJ. Influence of Proximal-Cervical Undermined Enamel Areas on Marginal Quality and Enamel Integrity of Laboratory and CAD/CAM Ceramic Inlays and Partial Crowns. Journal of Functional Biomaterials. 2025;16(3):82. doi:10.3390/jfb16030082

BibTeX
@article{Frankenberger2025,
  author = {Frankenberger, Roland and Friedrich, Katharina and Dudek, Marie-Christine and Winter, Julia and Krämer, Norbert and Roggendorf, Matthias J},
  title = {Influence of Proximal-Cervical Undermined Enamel Areas on Marginal Quality and Enamel Integrity of Laboratory and CAD/CAM Ceramic Inlays and Partial Crowns},
  journal = {Journal of Functional Biomaterials},
  year = {2025},
  volume = {16},
  number = {3},
  pages = {82},
  doi = {10.3390/jfb16030082}
}
Kostenlos starten →