EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Hybrid Biomechanical Design of Dental Implants: Integrating Solid and Gyroid Triply Periodic Minimal Surface Lattice Architectures for Optimized Stress Distribution

Dawit Bogale Alemayehu iD, Masahiro Todoh iD, Song-Jeng Huang iD

Journal of Functional Biomaterials · 09.02.2025 · 16 (2) · 54

DOI: 10.3390/jfb16020054 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Functional Biomaterials, online erschienen am 09.02.2025. Verfasst von Dawit Bogale Alemayehu und 2 weiteren Autor:innen. Beteiligte Einrichtung: Division of Human Mechanical Systems and Design, Graduate School of Engineering, Hokkaido University, Sapporo 060-8628, Japan. Die Arbeit wurde bisher 25-mal zitiert (Crossref) und nennt 83 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Science and Technology Council, MEXT Grant-in-Aid for Scientific Research, the National Science and Technology Council (Taiwan).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Dental implantology has evolved significantly since the introduction of additive manufacturing, which allows for the reproduction of natural bone’s porous architecture to improve bone tissue compatibility and address stress distribution issues important to long-term implant success. Conventional solid dental implants frequently cause stress shielding, which compromises osseointegration and reduces durability.

Aim

The current research proposes to examine the biomechanical efficacy of fully and hybrid gyroid triply periodic minimum surface (TPMS) latticed implants across different cell sizes to optimize stress distribution and improve implant durability.

Methods

This study evaluates six fully and hybrid gyroid (TPMS) latticed implants, including fully latticed designs with three cell sizes—FLI_111 (1 mm × 1 mm × 1 mm), FLI_222 (2 mm × 2 mm × 2 mm), and FLI_333 (3 mm × 3 mm × 3 mm)—and hybrid gyroid TPMS latticed implants with solid necks in corresponding sizes—HI_111, HI_222, and HI_333. To enhance initial stability, a square-threaded design was added into the bottom part of both fully and hybrid lattice implants. The designs also incorporate anti-rotational connections to enhance fixation, and they undergo a clinical viability comparison with contemporary implants. To improve lattice designs, finite element analysis (FEA) was utilized through nTopology (nTOP 4.17.3) to balance stiffness and flexibility. To examine mechanical performance under realistic conditions, a dynamic mastication loading simulation was conducted for 1.5 s across three cycles.

Results

The findings reveal that hybrid implants, particularly HI_222, exhibited improved mechanical characteristics by reducing micromotions at the bone–implant interface, improving osteointegration, and attaining better stress distribution.

Conclusions

By addressing stress shielding and boosting implant performance, this work paves the way for personalized implant designs, developing dental technology, and improving clinical results.

Schlagwörter

Stichwörter der Autor:innen

additive manufacturingbiomechanicaldental implantfinite element methodhybridimplantologyosseointegration

Autor:innen und Institutionen

  • Division of Human Mechanical Systems and Design, Graduate School of Engineering, Hokkaido University, Sapporo 060-8628, Japan.
  • Division of Mechanical and Aerospace Engineering, Faculty of Engineering, Hokkaido University, Sapporo 060-8628, Japan.
  • Department of Mechanical Engineering, National Taiwan University of Science and Technology, Taipei 10607, Taiwan.

ORCID-Profile: Dawit Bogale Alemayehu, Masahiro Todoh, Song-Jeng Huang

Förderung

  • National Science and Technology Council
  • MEXT Grant-in-Aid for Scientific Research
  • the National Science and Technology Council (Taiwan)

Zitieren

APA

Alemayehu, D. B., Todoh, M., & Huang, S. J. (2025). Hybrid Biomechanical Design of Dental Implants: Integrating Solid and Gyroid Triply Periodic Minimal Surface Lattice Architectures for Optimized Stress Distribution. Journal of Functional Biomaterials, 16(2), 54. https://doi.org/10.3390/jfb16020054

Vancouver

Alemayehu DB, Todoh M, Huang SJ. Hybrid Biomechanical Design of Dental Implants: Integrating Solid and Gyroid Triply Periodic Minimal Surface Lattice Architectures for Optimized Stress Distribution. Journal of Functional Biomaterials. 2025;16(2):54. doi:10.3390/jfb16020054

BibTeX
@article{Alemayehu2025,
  author = {Alemayehu, Dawit Bogale and Todoh, Masahiro and Huang, Song-Jeng},
  title = {Hybrid Biomechanical Design of Dental Implants: Integrating Solid and Gyroid Triply Periodic Minimal Surface Lattice Architectures for Optimized Stress Distribution},
  journal = {Journal of Functional Biomaterials},
  year = {2025},
  volume = {16},
  number = {2},
  pages = {54},
  doi = {10.3390/jfb16020054}
}
Kostenlos starten →