The Peroxidase-like Nanocomposites as Hydrogen Peroxide-Sensitive Elements in Cholesterol Oxidase-Based Biosensors for Cholesterol Assay
Journal of Functional Biomaterials · 07.06.2023 · 14 (6) · 315
DOI: 10.3390/jfb14060315 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Functional Biomaterials, online erschienen am 07.06.2023. Verfasst von Olha Demkiv und 5 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Cell Biology, National Academy of Sciences of Ukraine, 79005 Lviv, Ukraine. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 67 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Research Foundation of Ukraine, National Science Centre, Poland, FEBS Ukrainian Short-Term Fellowship.
Abstract (Originalsprache)
Catalytically active nanomaterials, in particular, nanozymes, are promising candidates for applications in biosensors due to their excellent catalytic activity, stability and cost-effective preparation. Nanozymes with peroxidase-like activities are prospective candidates for applications in biosensors. The purpose of the current work is to develop cholesterol oxidase-based amperometric bionanosensors using novel nanocomposites as peroxidase (HRP) mimetics. To select the most electroactive chemosensor on hydrogen peroxide, a wide range of nanomaterials were synthesized and characterized using cyclic voltammetry (CV) and chronoamperometry. Pt NPs were deposited on the surface of a glassy carbon electrode (GCE) in order to improve the conductivity and sensitivity of the nanocomposites. The most HRP-like active bi-metallic CuFe nanoparticles (nCuFe) were placed on a previously nano-platinized electrode, followed by conjugation of cholesterol oxidase (ChOx) in a cross-linking film formed by cysteamine and glutaraldehyde. The constructed nanostructured bioelectrode ChOx/nCuFe/nPt/GCE was characterized by CV and chronoamperometry in the presence of cholesterol. The bionanosensor (ChOx/nCuFe/nPt/GCE) shows a high sensitivity (3960 A·M−1·m−2) for cholesterol, a wide linear range (2–50 µM) and good storage stability at a low working potential (−0.25 V vs. Ag/AgCl/3 M KCl). The constructed bionanosensor was tested on a real serum sample. A detailed comparative analysis of the bioanalytical characteristics of the developed cholesterol bionanosensor and the known analogs is presented.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute of Cell Biology, National Academy of Sciences of Ukraine, 79005 Lviv, Ukraine.
- Faculty of Veterinary Hygiene, Ecology and Law, Stepan Gzhytskyi National University of Veterinary Medicine and Biotechnologies, 79000 Lviv, Ukraine.
- Institute of Physical Chemistry, Polish Academy of Sciences, 01-224 Warsaw, Poland.
- Department of Electronics and Information Technology, Lviv Polytechnic National University, 79000 Lviv, Ukraine.
ORCID-Profile: Nataliya Stasyuk
Förderung
- National Research Foundation of Ukraine
- National Science Centre, Poland
- FEBS Ukrainian Short-Term Fellowship
Zitieren
APA
Demkiv, O., Nogala, W., Stasyuk, N., Grynchyshyn, N., Vus, B., & Gonchar, M. (2023). The Peroxidase-like Nanocomposites as Hydrogen Peroxide-Sensitive Elements in Cholesterol Oxidase-Based Biosensors for Cholesterol Assay. Journal of Functional Biomaterials, 14(6), 315. https://doi.org/10.3390/jfb14060315
Vancouver
Demkiv O, Nogala W, Stasyuk N, Grynchyshyn N, Vus B, Gonchar M. The Peroxidase-like Nanocomposites as Hydrogen Peroxide-Sensitive Elements in Cholesterol Oxidase-Based Biosensors for Cholesterol Assay. Journal of Functional Biomaterials. 2023;14(6):315. doi:10.3390/jfb14060315
BibTeX
@article{Demkiv2023,
author = {Demkiv, Olha and Nogala, Wojciech and Stasyuk, Nataliya and Grynchyshyn, Nadiya and Vus, Bohdan and Gonchar, Mykhailo},
title = {The Peroxidase-like Nanocomposites as Hydrogen Peroxide-Sensitive Elements in Cholesterol Oxidase-Based Biosensors for Cholesterol Assay},
journal = {Journal of Functional Biomaterials},
year = {2023},
volume = {14},
number = {6},
pages = {315},
doi = {10.3390/jfb14060315}
}
EUVIMED