EUVIMEDEUVIMED entdecken
Crossref

A novel electrochemical strategy to detect hydrogen peroxide by utilizing peroxidase-mimicking activity of cerium oxide/graphene oxide nanocomposites

Sunghyeon Kim, Shin Chan Kang, Sang Mo Lee, Jinhwan Lee, Youngran Cho, Yeonjin Shim, Hyun Gyu Park

Biosensors and Bioelectronics · 2024-06 · 253 · 116161

DOI: 10.1016/j.bios.2024.116161 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2024-06. Verfasst von Sunghyeon Kim und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemical and Biomolecular Engineering (BK21 four), Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-g…. Hauptthemen laut MEDLINE: Biosensing Techniques, Graphite, Cerium, Nanocomposites. Die Arbeit wurde bisher 30-mal zitiert (Crossref) und nennt 44 Literaturangaben. Gefördert von: Ministry of Science, ICT and Future Planning, National Research Foundation, National Research Foundation of Korea.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

We herein describe a novel electrochemical strategy to detect hydrogen peroxide (H2O2) by utilizing the peroxidase-mimicking activity of cerium oxide nanoparticles (CeO2 NP) and reduced graphene oxide (rGO). Particularly, CeO2 NP/rGO nanocomposites were deposited on the commercial electrode by a very convenient and direct electrochemical reduction of graphene oxide. Due to the peroxidase-mimicking activity of CeO2 NP and the outstanding electrochemical properties of reduced graphene oxide, the reduction current of H2O2 was greatly enhanced. Based on this strategy, we reliably determined H2O2 down to 1.67 μM with excellent specificity and further validated its practical capabilities by robustly detecting H2O2 present in heterogeneous human serum samples. We believe that this work could serve as a new facile platform for H2O2 detection.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesGraphiteCeriumNanocompositesHumansHydrogen PeroxidePeroxidasesElectrochemical Techniques

Stichwörter der Autor:innen

Cerium oxide nanoparticlesHydrogen peroxidePeroxidase activityReduced graphene oxide

Substanzen

graphene oxideHydrogen Peroxideceric oxideGraphiteCeriumPeroxidases

Autor:innen und Institutionen

  • Department of Chemical and Biomolecular Engineering (BK21 four), Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea.
  • Department of Chemical and Biomolecular Engineering (BK21 four), Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea. Electronic address: hgpark@kaist.…

Förderung

  • Ministry of Science, ICT and Future Planning
  • National Research Foundation
  • National Research Foundation of Korea
  • Korea Ministry of Science and ICT

Zitieren

APA

Kim, S., Kang, S. C., Lee, S. M., Lee, J., Cho, Y., Shim, Y., & Park, H. G. (2024). A novel electrochemical strategy to detect hydrogen peroxide by utilizing peroxidase-mimicking activity of cerium oxide/graphene oxide nanocomposites. Biosensors and Bioelectronics, 253, 116161. https://doi.org/10.1016/j.bios.2024.116161

Vancouver

Kim S, Kang SC, Lee SM, Lee J, Cho Y, Shim Y, et al. A novel electrochemical strategy to detect hydrogen peroxide by utilizing peroxidase-mimicking activity of cerium oxide/graphene oxide nanocomposites. Biosensors and Bioelectronics. 2024;253:116161. doi:10.1016/j.bios.2024.116161

BibTeX
@article{Kim2024,
  author = {Kim, Sunghyeon and Kang, Shin Chan and Lee, Sang Mo and Lee, Jinhwan and Cho, Youngran and Shim, Yeonjin and Park, Hyun Gyu},
  title = {A novel electrochemical strategy to detect hydrogen peroxide by utilizing peroxidase-mimicking activity of cerium oxide/graphene oxide nanocomposites},
  journal = {Biosensors and Bioelectronics},
  year = {2024},
  volume = {253},
  pages = {116161},
  doi = {10.1016/j.bios.2024.116161}
}
Kostenlos starten →